Manual
Reset
4.44
Closing
S50,
the
MANUAL
RESET
push
button,
puts a '0'
on
IC17q!2.
The
resulting
'1'
at
IC17q!12,
inverted
in IC3b
is
applied
to
ICllb/4,
giving
a
'1'
at
IC4/13
and
putting
the
counter
into
the
HOLD
state.
The
:0'
from S50
is
also
applied
to
IC2q!9.
This
gives
a
negative
going
pulse,
of
duration
determined
by
R17ljC71
at
IC2q/12and
IC17q!13.
This
overcomes
any
contact
bounce
effects
in
S50.
4.45
Releasing
55Q
allows
IC4/13
to
revert
to
'Q'
and
a
new
n;Jeasurement
cycle
to
start.
The
'Q'
to
'1'
transition
at
IC3b/4
is
appl
ied
to
1C13q/2,
giving
a
'0'
at
IC2b/l.
This
gives
a
positive
going
pulse
at
IC2b/13which
is
inverted
in
IC3c
to
give
a
negative
9,?ing
pulse
at
IC4/4.
This
unlatches
and
clears
the
stores
ready
for
the
new
measurement.
External Hold
and
Reset
4.46
The
application
of
a
'0'
at
pin
6
of
the
Data
Output
socket
results in a
'1'
at
ICllb/6
and
IC4/13.
Provided
this
is
appl
ied
in
accordance
with
the
conditions
in
paragraph
3.11
the
counter
will
go
into
the
H01
d
state
at
the
end
of
the
measurement
in
progress.
4.47
The
application
of
a
'Q'
at
pin
7
of
the
Data
Output
socket
results in
operation
of
the
reset
circuit
as
described
in
paragraphs
4.44
and
4.45
except
that
no
bounce
protection
is
provided
by
IC2a.
BURST
MODE
Summary
of
Operation
4.48
With
the
FUNCTION
switch
set
to
BURST
the
counter
is
put
into
the
Hold
state.
Pressing
the
RESET
button
extinguishes
the
display
except
for
the
decimal
point.
The
incoming
signal
to
be
measured
causes
the
counter
to
reset
and
commence
a
'one-shot'
measurement
..
As
measurement
commences
the
display
shows
all
zeros.
At
the
end
of
the
measurement
period
the
display
is
updated
and
the
counter
reverts
to
the
Hold
state.
A
fresh
cycle
is
initiated
by
pressing
and
releasing
the
RESET
push
button.
Circuit
Operation
4.49
When
BURST
is
selected
the
Burst
Select
line
is
at
'1'.
ICl7c
therefore
has
all
its inputs
at
'1',
provided
Q26
is
on
(se~
paragraph
4.43).
This
produces
a
'0'
at
ICl7b/5
and
a
'1'
at
IC4/13,
putting
the
counter
into
the
Hold
state.
4-7
9916Vol.2

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Racal Instruments 9916 and is the answer not in the manual?

Racal Instruments 9916 Specifications

General IconGeneral
BrandRacal Instruments
Model9916
CategoryMeasuring Instruments
LanguageEnglish