2.1.6. COMBUSTION BLOWER FREQUENCY/HEAT CAPACITY DIAGRAM
GAS TYPE
MINIMUM
HEATING
FREQUENCY
MAXIMUM
HEATING
FREQUENCY
MINIMUM
FREQUENCY IN
DOMESTIC HOT
WATER LINE
MAXIMUM
FREQUENCY IN
DOMESTIC HOT
WATER LINE
Natural
Gas
Hz 45 172 45 186
Propane Hz 45 172 45 186
Note: The frequency would change based on vent length. See section ‘1.1.21 TABLE 1: ALLOWABLE
VENT LENGTHS’ for change on frequency with feference to vent lengths.
2
4
6
8
10
12
14
16
18
20
22
24
26
35 50 65 80 95 110 125 140 155 170 185
(kW)
(Hz)
(btu/h)
6824
13648
20472
27297
34121
40945
47769
54594
61418
68242
75067
81891
88715
Natural Gas