Response options:
CU0_I CR LF
- command understood but not accessible at this moment
CU0_A CR LF
- command understood and carried out
Set min checkweighing threshold
Format: DH_XXXXX CR LF, where: _ - space, XXXXXmass format
Response options:
DH_OK CR LF
- command carried out
ES CR LF
- command not recognised (mass format incorrect)
Set max checkweighing threshold
Format: UH_XXXXX CR LF, where: _ - space, XXXXX - mass format
Response options:
UH_OK CR LF
- command carried out
ES CR LF
- command not recognised (mass format incorrect)
Give value of min checkweighing threshold
Format: ODH CR LF
Response: DH_MASA CR LF - command carried out
Response format:
1 2 3 4-12 13 14 15 16 17 18 19
D H space mass space unit space CR LF
Mass
- 9 characters with right justification
Unit
- 3 characters with left justification
Give value of max checkweighing threshold
Format: OUH CR LF
Response: UH_MASA CR LF - command carried out
Response format:
1 2 3 4-12 13 14 15 16 17 18 19
U H space mass space unit space CR LF
Mass
- 9 characters with right justification
Unit
- 3 characters with left justification
Set mass value of a single item (only for PARTS COUNTING)
Format: SM_XXXXX CR LF, where: _ - space, XXXXXmass format
Response options:
SM_OK CR LF
- command carried out
SM_I CR LF
- command understood but not accessible at this moment (e.g. mode other than
PARTS COUNTING)
ES CR LF
- command not recognised (mass format incorrect)
Set target mass value (e.g. for DOSING)
Format: TV_XXXXX CR LF, where: _ - space, XXXXX - mass format
Response options:
TV_OK CR LF
- command carried out
TV_I CR LF
- command understood but not accessible at this moment (e.g. mode other than
DOSING)
ES CR LF
- command not recognised (mass format incorrect)
Set reference mass value (e.g. for PERCENT WEIGHING)
Format:
RM_XXXXX CR LF
, where:
_ -
space
,
XXXXX
mass format
Response options:
RM_OK CR LF
- command carried out
RM_I CR LF
- command understood but not accessible at this moment (e.g. mode other than
PERCENT WEIGHING)
ES CR LF
- command not recognised (mass format incorrect)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the RADWAG AS PLUS Series and is the answer not in the manual?

RADWAG AS PLUS Series Specifications

General IconGeneral
DisplayLCD with backlight
Power Supply100-240 V AC 50/60 Hz
CalibrationInternal / External
InterfaceRS232, USB-A, USB-B
Operating Temperature+10° - +40°C
Pan Sizeø 85 mm
Repeatability0.1 mg
Linearity±0.2 mg
Stabilization time2-3 seconds