[SENSe<Ch>:]PRANge <Power Range, Tmp command>
Suffix:
<Ch>
.
Parameters:
<Power Range, Tmp
command>
CALCulate<Chn>:FORMat:WQPNormal <Boolean>
Enables phase normalization for wave quantity traces.
Suffix:
<Chn>
.
Channel number used to identify the active trace
Parameters:
<Boolean> If set to ON, the phase of the measured wave quantity is normal-
ized to the a-wave of the selected driving port.
SYSTem:CORRection:FMPort[:STATe] <arg0>
Enables or disables Fast Multiport Correction.
Parameters:
<arg0> ON | OFF – Enable or disable fast multiport correction.
*RST: *RST has no effect on the calibration algorithm.
Example:
SYST:CORR:FMP ON
Enable fast multiport correction.
7.3.20.5 List of Commands
[SENSe<Ch>:]CORRection:POWer:MIXer:IF:ACQuire...............................................................................1532
[SENSe<Ch>:]FREQuency:CONVersion:MIXer:PRFimage........................................................................ 1533
[SENSe<Ch>:]FREQuency:MDELay:ACQuire............................................................................................ 1535
[SENSe<Ch>:]FREQuency:MDELay:APERture..........................................................................................1535
[SENSe<Ch>:]FREQuency:MDELay:CDELay.............................................................................................1536
[SENSe<Ch>:]FREQuency:MDELay:CDMode............................................................................................1536
[SENSe<Ch>:]FREQuency:MDELay:CONVersion......................................................................................1537
[SENSe<Ch>:]FREQuency:MDELay:CORRection[:STATe]........................................................................ 1537
[SENSe<Ch>:]FREQuency:MDELay:DIVide............................................................................................... 1537
[SENSe<Ch>:]FREQuency:MDELay:LTONe...............................................................................................1538
[SENSe<Ch>:]FREQuency:MDELay:RECeiver...........................................................................................1538
[SENSe<Ch>:]FREQuency:MDELay:RPORt...............................................................................................1538
[SENSe<Ch>:]FREQuency:MDELay:UTONe..............................................................................................1538
[SENSe<Ch>:]FREQuency:OFFSet:PWAVes:STATe.................................................................................. 1541
[SENSe<Ch>:]FREQuency<Pt>:OFFSet:PWAVes......................................................................................1541
[SENSe<Ch>:]FREQuency<Pt>:OFFSet:WAVes........................................................................................1541
[SENSe<Ch>:]MSMode...............................................................................................................................1542
[SENSe<Ch>:]PPORt<PPort>:BSHift..........................................................................................................1542
SCPI command reference

Table of Contents

Other manuals for R&S ZNA26

Related product manuals