40
13. Technical Data
THE COOKER IS CATEGORY: CatII
2H3+
.
It is supplied set for group H natural gas. A conversion kit from NG to LP is available for the cooker.
INSTALLER: Please leave these instructions with the user.
DATA BADGE LOCATION: Cooker back, serial number repeater badge below oven door opening.
COUNTRY OF DESTINATION: GB, IE.
Connections
Gas (Rp ½ at rear right-hand side) Electric
Natural Gas
20 mbar
230/400 V 50 HzButane 29 mbar
Propane 37 mbar
See the appliance badge for test pressures.
Dimensions
Model Classic 90 Dual Fuel
Overall height minimum 905 mm maximum 930
mm
Overall width 900 mm
Overall depth 608 mm excluding handles, 670 mm including handles
Minimum height above the hotplate
650 mm
Model Kitchener 90 Dual Fuel
Overall height minimum 905 mm maximum 930 mm
Overall width 900 mm
Overall depth 604 mm excluding handles, 652 mm including handles
Minimum height above the hotplate 650 mm
Model Professional + 90 Dual Fuel
Overall height minimum 905 mm maximum 930 mm
Overall width 900 mm
Overall depth 604 mm excluding handles, 642 mm including handles
Minimum height above the hotplate 650 mm