54
3) Return to the rst column, the MASTER and the display will show:
> > C H 2 C O L 4 < <
C o n f. C o p l ?
(radio channel CH 2) (COL 2 - are the columns that form the power lift (2-4-6-8))
The operator must accept that the number of columns is equal to the total number of congured columns (including the Master).
If this condition is satised, then it is possible to close the conguration:
move down with the blue Key
, to
C H 2 C O L 4
> > C o n f. C o m p l ? < <
conrm with the black “ENTER” key
In case the number of columns shown on the display of the MASTER column is different from the columns that you want to con-
gure, you must repeat the entire setup process from start by turning off and on all the columns.
If the number of the congured columns is different from (2-4-6-8), the Master column shall show the following error message:
W R O N G C O L U M N S
N U M B E R R E T R Y?
If the conguration is successful, the display will show:
H e i g h t 0 0 0 0 mm
G R O U N D A L L
B) LAST conguration
ATTENTION: THE OLD CONFIGURATION IS CANCELLED EACH TIME THE
COLUMNS REACH ALL THE RESET LIMIT SWITCHES (ALL LOW) AND THE
COLUMNS ARE OFF.
IN THIS CASE, ON SWITCHING BACK ON AND SELECTION OF THE OLD CON-
FIGURATION ON ONE OF THE COLUMNS, THE MESSAGE “NEW CONFIGURATION NECESSARY” APPEARS.
FROM THIS CONDITION, YOU MUST RESTART BY SWITCHING OFF AND BACK ON THE LIFT AND ALWAYS EXECUTING
A NEW CONFIGURATION.
THIS PRECAUTION COMPLIES WITH THE SAFETY PRINCIPLE WHICH AVOIDS CONFUSING DIFFERENT COLUMNS SETS
ONCE ALL THE TROLLEYS ARE BROUGHT BACK TO THE GROUND.
Selecting this option allows you to restart with the same conguration as the previous shutdown: same Radio channel number (ID),
same columns (CH) and same heights and any quota offset from previous single or group operations.
1) When starting the switchboard, the following shall appear:
> > L A S T C O N F I G < <
N E W C o n f i g
conrm with the black “ENTER” key
1A) Caution: In the event that a previous valid conguration is not stored, the display will show:
> > L A S T C O N F I G < <
N O T S T O R E D
after this message the system automatically returns to the initial screen.
2) N.B: Repeat the operation described in paragraph 1 on all the columns in the selected conguration.
After selecting this option, the MASTER column checks if the previously used radio channel is still available and if there is com-
munication with all of the columns, in which case the display will show:
L A S T C O N F I G I D 1
M S T C H 2 C O L 2
MASTER column (ID 1 is always the master column)
L A S T C O N F I G I D 2
S L A V E C H 2
SLAVE column (ID2 to ID8 are the SLAVE columns)
7
NUOVA CONFIGURAZ
NECESSARIA
NUOVELLE CONFIG
NECESSAIRE
NEW CONFIG
NEEDED