6.7 Error messages
ERROR MESSAGES
Load cell signal is unstable
Automatic after removing weight
Gross negative. This action is not allowed
Sampling accuracy too low
Automatic after correcting input
Calibration out of range (negative)
Calibration out of range (signal too low)
Calibration count 2nd(3rd) point lower than count
1st(2nd) point
Setpoint value 2 < setpoint value 1. This is not allowed
Legal for trade version: not allowed action
Calibration point must be higher than previous one
When action is intended, install jumper JP1
( attention: after this action a complete
new calibration and stamping of the
system is necessary )
Automatic
Err99
ErrF1
ErrF2
----
L - _
ErrCS
+F1
+F2
Action only allowed in start-up units
Problem with fork 1 (no communication)
Problem with fork 2 (no communication)
Loadcell signal negative
Forks are out of level (only legal-for-trade version)
Problem with correction sensor
Battery of indicator is empty
Battery of fork 1 is empty
Battery of fork 2 is empty
Automatic
Restart indicator. Restart forks & indicator
Restart indicator. Restart forks & indicator
Lift up the forks from the ground
Put the forks into horizontal position
Contact the RAVAS Service department
Replace the 4 AA batteries
Replace the D-cells in both battery packs or
charge both battery packs
Replace the D-cells in both battery packs or
charge both battery packs
Successful Bluetooth link with fork 1
Successful Bluetooth link with fork 2