3
Manual No. 016-0130-076 Rev. C 13
Calibration
6. Touch the master power icon at the bottom of the tab to toggle the AutoBoom
system on.
7. On the implement joystick or control panel, press and hold the center rack raise
function for 6 seconds.
Note: Continue to hold the raise function for the full 6 seconds even if the center rack reaches the upper
limit of travel during this time.
8. On the implement joystick or control panel, press and hold the center rack lower function for 6 seconds.
Note: Continue to hold the lower function for the full 6 seconds even if the center rack reaches the lower
limit of travel during this time.
XT Control Calibration (If Equipped)
Complete the following procedure to calibrate the center rack tilt control feature:
1. Complete the calibration procedure for the left and right booms. Refer to the Boom Calibration section on
page 11 to complete the boom calibration process.
2. Touch the Edit icon in the Machine Configuration panel to expand the panel.
3. Locate and select the AutoBoom button. The AutoBoom Features tab will be displayed.
4. Verify that the XT Control option is selected.
Note: Be sure that the required components for XT Control are installed prior to enabling these
additional features.
5. Select the Calibrate tab.
6. Select the Forward Pointing Arrow value and use the scroll menu to select the arrow number on the node
enclosure which is pointing toward the front of the implement. Refer to the Forward Pointing Number
section on page 21 for additional assistance with this setting.
7. Touch the master power icon at the bottom of the tab to toggle the AutoBoom
system on.
8. Touch the Start Calibration icon displayed above the center section.
Note: If the machine has an open center hydraulic system, or the type of hydraulic system is
unknown, all calibration procedures should be performed with the engine at the normal
operating RPM.
WARNING
Booms will raise and lower automatically and
may do so quickly or suddenly during the
calibration process. To avoid serious injury or
damage to the booms, check the area around
the implement and keep bystanders and
obstructions clear of boom travel during the
AutoBoom calibration process.
Edit AutoBoom CalibrateFeatures