Chapter 3
22 AutoBoom® Calibration & Operation Manual
Manual Control Tab
1. Touch the Edit icon in the Machine Configuration panel to expand the panel.
2. Locate and select the AutoBoom button.
3. Touch the Manual Control tab to access the on-screen manual controls.
Boom Status Display
The current monitored height and hydraulic pressure for each implement section is displayed on the Manual
Control tab. These displays may be useful to prepare the system for calibration or help to indicate issues with
the system during the calibration process.
A more detailed display of sensor height and hydraulic pressure is available on the Diagnostics tab. Refer to
the Diagnostics Tab section on page 23 for more information.
Manual Controls
The manual controls may be used to help troubleshoot wiring or hydraulic issues experienced with the
AutoBoom system. The up and down manual controls for the left, center, and right sections allow the
implement operator to manually raise and lower the booms via the AutoBoom system to verify function of the
system without engaging AutoBoom.
Note: The machine valve will be used to control center rack functionality if the machine is equipped with
center rack control and required center rack control cabling has been installed.
Manual Speed Adjustment
Use the left and right arrow buttons to adjust the speed at which the AutoBoom valve manually raises or lowers
the booms on implements that do not have a remote or SVC hydraulic control. Since most implements are
equipped to hydraulically control boom functions, the default up and down speeds are set to zero.
XT Control
(UltraGlide XT Systems Only) Allows the operator to rotate the center rack clockwise and counterclockwise
relative to the implement chassis. These functions may be used to troubleshoot issues with the XT Control
system and verify that the XT valve is connected correctly.
Edit AutoBoom Manual
Control
UltraGlide XT SystemsPowerGlide Plus Systems