Appendix A
44 AutoBoom® Calibration & Operation Manual
FIGURE 4. Port Plug Removal
4. Place the AutoBoom valve on its side and use the Allen wrench to remove the orifice fittings from both ports
3A and 3B.
Note: Keep the orifice fittings removed from ports 3A and 3B for future use. These fittings will be required
to convert the AutoBoom hydraulic valve back to UltraGlide mode.
FIGURE 5. Orifice Fitting Removal
5. Use an Allen wrench to reinstall the port plugs into the cavities in ports 3A and 3B.
6. Replace the coils on the solenoids.
WARNING
Do not let the fitting fall into the hydraulic valve.
Obstructions in the hydraulic valve will
adversely affect system performance or
damage the hydraulic valve.
Port Plug Removed
from port 3A