TheAlarmHistorytabprovidesdetailsofalarms
andthedateandtimethattheyweretriggeredand
cleared/acknowledged.TheAlarmhistorycan
displayupto1,000alarmeventsanddisplaysthem
sortedbytime.
WhentheAlarmhistoryhasreacheditscapacity
of1,000entries,theoldesteventsinthelistwillbe
automaticallydeletedwhensubsequentnewalarm
eventsoccur.
Alarmeventswillonlyberemovedfromthelistif:
Clearalarmhistoryisselected.
aSystemsandDataResetisperformed.
itisautomaticallydeletedduetothelistreaching
itscapacityof1,000events.
ActiveAlarms
TheActiveAlarmtablistsallcurrentlyactivealarms.
Alarmsareremovedfromthelistwhen:
theconditionsthattriggeredthealarmareno
longerpresent.
thealarmhasbeendisabled.
AccessingtheAlarmManager
FromtheHomescreen:
1.SelectSet-up.
2.SelectAlarms.
TheAlarmManagerisdisplayed.
Enablinganddisablinganalarm
YoucanenableanddisablealarmsusingtheAlarm
Manager.
FromtheAlarmManagerHomescreen>Set-up>
Alarms:
1.SelecttheSettingstab.
2.Selectthealarmcategoryforthealarmyouwant
toenable/disable.
AlarmsaredisplayedintheAlarmManagerin
thefollowingcategories:
SafetyAlarms
GeneralAlarms
*SwitchPanelAlarms
EngineAlarms
Note:*TheSwitchPanelAlarmscategoryisonly
displayedwhenyouhaveacorrectlycongured
RaymarineDigitalSwitchingsysteminstalledon
yourvessel.
3.Selectontherelevantalarm.
AlarmswithBlacktextarecurrentlyenabledand
alarmswithGraytextarecurrentlydisabled.
Thealarmwillbeexpandedtoshowthealarm
settings.
IftheEnableboxistickedthenthealarmis
currentlyenabled.
4.T odisablethealarm,selecttheEnabletickbox
sothatthetickisremoved.
5.T oenablethealarm,selecttheEnabletickbox
sothatatickisdisplayed.
Changingalarmthresholds
Alarmthresholdsaretheattributesassociatedwith
eachalarmwhichdictateswhenthealarmeventis
triggered.
WiththeAlarmManagerdisplayed:
1.SelecttheSettingstab.
2.Selectthealarmcategoryforthealarmyouwant
tochangethethresholdsof.
3.Selectontherelevantalarm.
Thealarmwillbeexpandedtoshowthealarm
settings.
4.Selecttherelevantthreshold.
Thenumericadjustmentcontrolisdisplayed.