Circuit breaker and fuse information
Select the appropriate circuit breaker or fuse for your system using the table below as
a guide.
To connect the power and drive unit
• Fit the power cable to the distribution panel.(We recommend using a dedicated
circuit breaker for the power cable).
• Route the power cable to the SPX SmartPilot and fit it to the POWER INPUTS ter-
minal.
• Connect the drive cables to the DRIVE MOTOR OUTPUTS terminal.
• Connect the drive to the DRIVE CLUTCH OUTPUTS.
Motor phasing is determined during commissioning: refer to separate commissioning
guide for further information.
Type 3 drive 12 V (X30) up to 5m (16ft) 8 AWG
10 mm
2
Type 3 drive 24 V (X30) up to 5m (16ft) 10 AWG
6 mm
2
up to 7m (23ft) 8 AWG
10 mm
2
Drive unit Fuse Thermal over-current circuit
breaker
Rotary drive
Linear drive
Hydraulic pump
Hydraulic linear
Type 1, 12 V 25 A 20 A
Type 1,24 V 25 A 20 A
Type 2, 12 V 40 A 30 A
Type 2, 24 V 30 A 30 A
Type 3,
12V and 24V
40 A 30 A
I/O 15 A 10 A
CR pump solenoids 10 A 10 A
Drive type Cable length Cable gauge Copper area