40
3.13 Test the system
Switch on
Switch on the main power breaker.
SeaTalk
ng
If you are using an ST70 autopilot controller and it does not power up:
Switch it on by holding down the Power button for 1 second.
If the SPX SmartPilot and autopilot controller are active, the autopilot control-
ler should display a select LANGUAGE menu.
Troubleshooting
If the display is blank, check the fuse/circuit breaker, the SeaTalk
ng
fuse in the SPX
SmartPilot computer and that the SeaTalk
ng
power switch is set to ON.
If the display shows the SEATALK
ng
FAIL or NO DATA alarm message, check the
SeaTalk
ng
connections and terminators.
SeaTalk
If you are using a SmartPilot controller (ST6002, ST7002 or ST8002) and it
does not power up:
Hold down the Display button for 1 second.
If the SPX SmartPilot and autopilot controller are active, the autopilot control-
ler should display a STANDBY screen.
Troubleshooting
If the display is blank, check the fuse/circuit breaker, the SeaTalk fuse in the SPX
SmartPilot computer.
If the display shows the SEATALK
ng
FAIL or NO DATA alarm message, check the
SeaTalk
connections and terminators.
If the STANDBY screen does not display a live compass heading or a rudder
angle, check the sensor connections.
3.14Final fix
After connecting any additional components, make sure the system is powered down
before finally securing all equipment properly in place.
87072-2.book Page 40 Thursday, November 22, 2007 8:43 AM

Other manuals for Raymarine SPX 10