For new measuring head you have to install (by using eS Install) an appropriate unified type
(indicated in the calibration protocol).
If you use User’s type, it is necessary to perform automatic zero installation again, and then
by additional manual zero installation (see Appendix 1) to set for an empty probe (firstly you
should remove the probe from the fuel and wait until the fuel drain) the same level code as
specified in the calibration protocol of this tank.
Install and connect a new measuring head, make the sensor sealing in accordance with the
requirements of section 8.
Partial removal of the sensor is made as follows:
Disconnect the interface and connecting cables.
Remove only the measuring head of the sensor.
If necessary, partially tighten the sleeve of the sensor’s probe into the flange, as shown in
Pic. 10.1.
Close the sleeve of the sensor’s probe by a cap.
Pic. 10.1 Partial removal of fuel level sensor
Complete removal of the sensor is made as follows:
Disconnect the interface and connecting cables.
Remove the measuring head and then the sensor’s probe from the flange.
Close the hole of the flange by the plug M 25 x 1.5 (see Table 3), as shown in Pic. 10.2.
Pic. 10.2 Complete removal of fuel level sensor