INSTALLATION INSTRUCTIONS (continued)
18
Fit 2nd flue clamp loosely onto the 65mm section of
f
lue.
Lift fan assembly into appliance and locate onto flue
c
onnection. Insert fully. Locate fan in the required
direction. Screw fan assembly down onto the
appliance. (Screws prefitted into holes are located on
the appliance for direct out back connection and 90°
to right connection.)
(Note 90° left connection is not available and must be
done using the 90° right connection fan location and
placing a bend in the flue to head in the LH direction.
Locate 2nd clamp onto lower connection and tighten clamp fully.
Wipe excess silicon, visually check connection to ensure connection is fully sealed.
3/ Fit hot exhaust flue pipe from outlet termination to fan outlet connection.
Cut tube to length where required.
Ensure ends are burr free and round, test fit flue will slide over connection.