31
REGISTER
ADDRESS
REGISTER NAME LOW LIMIT HIGH LIMIT
FACTORY
SETTING
ACCESS COMMENTS
40406 Line 2 Units Mnemonic Digit 3 0 54 0 Read/Write
40407 Line 2 Units Mnemonic Digit 4 0 54 0 Read/Write
40408 Line 2 Units Mnemonic Digit 5 0 54 0 Read/Write
40409 Line 2 Units Mnemonic Digit 6 0 54 0 Read/Write
40410 Line 2 Units Mnemonic Digit 7 0 54 0 Read/Write
40411 Line 2 Units Mnemonic Digit 8 0 54 0 Read/Write
40412 Line 2 Units Mnemonic Digit 9 (Right) 0 54 0 Read/Write
40413 Line 2 Counter A Display Access 0 2 0 Read/Write 0=LOC, 1=d-rEAd, 2=d-rSt
40414 Line 2 Counter B Display Access 0 2 0 Read/Write 0=LOC, 1=d-rEAd, 2=d-rSt
40415 Line 2 Counter C Display Access 0 2 0 Read/Write 0=LOC, 1=d-rEAd, 2=d-rSt
40416 Line 2 Rate A Display Access 0 2 0 Read/Write 0=LOC, 1=d-rEAd
40417 Line 2 Rate B Display Access 0 2 0 Read/Write 0=LOC, 1=d-rEAd
40418 Line 2 Rate C Display Access 0 2 0 Read/Write 0=LOC, 1=d-rEAd
40419 Line 2 Max (Hi) Value Access 0 2 0 Read/Write 0=LOC, 1=d-rEAd, 2=d-rSt
40420 Line 2 Min (Lo) Value Access 0 2 0 Read/Write 0=LOC, 1=d-rEAd, 2=d-rSt
40421 Line 2 List A/B Selection Access 0 5 0 Read/Write 0=LOC, 1=d-rEAd, 2=d-Entr, 3=P-rEAd, 4=P-Entr, 5=HidE
40422 List A/B Parameter Assignment 0 15 0 Read/Write
Selects List A/B Parameter values (Bit State: 0 = No, 1 =
Yes): Bit 3 = Units Mnemonics
40423 Line 2 Setpoint 1 Value Access 0 5 0 Read/Write 0=LOC, 1=d-rEAd, 2=d-Entr, 3=P-rEAd, 4=P-Entr, 5=HidE
40424 Line 2 Setpoint 2 Value Access 0 5 0 Read/Write 0=LOC, 1=d-rEAd, 2=d-Entr, 3=P-rEAd, 4=P-Entr, 5=HidE
40425 Line 2 Setpoint 3 Value Access 0 5 0 Read/Write 0=LOC, 1=d-rEAd, 2=d-Entr, 3=P-rEAd, 4=P-Entr, 5=HidE
40426 Line 2 Setpoint 4 Value Access 0 5 0 Read/Write 0=LOC, 1=d-rEAd, 2=d-Entr, 3=P-rEAd, 4=P-Entr, 5=HidE
40427 Line 2 Scale Factor A Display Access 0 2 0 Read/Write 0=LOC, 1=P-rEAd, 2=P-Entr, 3=HidE
40428 Line 2 Scale Factor B Display Access 0 2 0 Read/Write 0=LOC, 1=P-rEAd, 2=P-Entr, 3=HidE
40429 Line 2 Scale Factor C Display Access 0 2 0 Read/Write 0=LOC, 1=P-rEAd, 2=P-Entr, 3=HidE
40430 Line 2 Count Load A Display Access 0 2 0 Read/Write 0=LOC, 1=P-rEAd, 2=P-Entr, 3=HidE
40431 Line 2 Count Load B Display Access 0 2 0 Read/Write 0=LOC, 1=P-rEAd, 2=P-Entr, 3=HidE
40432 Line 2 Count Load C Display Access 0 2 0 Read/Write 0=LOC, 1=P-rEAd, 2=P-Entr, 3=HidE
40433 Line 2 Display Color Access 0 3 0 Read/Write 0=LOC, 1=P-rEAd, 2=P-Entr, 3=HidE
40434 Line 2 Display Intensity Level Access 0 3 0 Read/Write 0=LOC, 1=P-rEAd, 2=P-Entr, 3=HidE
40435 Line 2 Display Contrast Level Access 0 3 0 Read/Write 0=LOC, 1=P-rEAd, 2=P-Entr, 3=HidE
Line 2 User Function Access
40451 Reset Line 1 Function Access 0 2 0 Read/Write 0=LOC, 1=P-Entr, 2=HidE
40452 Reset Counter A Function Access 0 2 0 Read/Write 0=LOC, 1=P-Entr, 2=HidE
40453 Reset Counter B Function Access 0 2 0 Read/Write 0=LOC, 1=P-Entr, 2=HidE
40454 Reset Counter C Function Access 0 2 0 Read/Write 0=LOC, 1=P-Entr, 2=HidE
40455 Reset Counter A,B,C Function Access 0 2 0 Read/Write 0=LOC, 1=P-Entr, 2=HidE
40456 Reset Max (Hi) Function Access 0 2 0 Read/Write 0=LOC, 1=P-Entr, 2=HidE
40457 Reset Min (Lo) Function Access 0 2 0 Read/Write 0=LOC, 1=P-Entr, 2=HidE
40458 Reset Max & Min Function Access 0 2 0 Read/Write 0=LOC, 1=P-Entr, 2=HidE
40459 Print Request Function Access 0 2 0 Read/Write 0=LOC, 1=P-Entr, 2=HidE
PORT PARAMETERS SEE PORT MODULE FOR PARAMETER DESCRIPTIONS
USB
40481 USB Configuration 0 1 0 Read/Write 0 = Automatic, 1 = Serial
Serial
40482 Type 0 2 2 Read/Write
0 = RLC Protocol (ASCII), 1 = Modbus RTU, 2 = Modbus
ASCII
40483 Baud Rate 0 5 5 Read/Write 0=1200, 1=2400, 2=4800, 3=9600, 4=19200, 5=38400
40484 Data Bits 0 1 1 Read/Write 0 = 7 Bits, 1 = 8 Bits
40485 Parity 0 2 0 Read/Write 0 = None, 1 = Even, 2 = Odd
40486 Address
099
247 Read/Write
RLC Protocol: 0-99
1 247 Modbus: 1-247
40487 Transmit Delay 0 250 10 Read/Write 1 = 0.001 Seconds
40488 Abbreviated Transmission (RLC only) 0 1 0 Read/Write
0 = No, 1 = Yes (Not used with Modbus communications
type)
40489 Print Options (RLC only) 0 2047 1 Read/Write
0 = No, 1 = Yes (Not used with Modbus communications
type)
Bit 0 = Count A, Bit 1 = Count B, Bit 2 = Count C, Bit 3 =
Rate A, Bit 4 = Rate B, Bit 5 = Rate C, Bit 6 = Hi (max), Bit 7
= Lo (min), Bit 8 = Scale Factors, Bit 9 = Count Load Values,
Bit 10 = Setpoint Values
40490 Load Serial Settings 0 1 0 Read/Write
Changing 40481-40487 will not update the PAX2 until this
register is written with a 1. After the write, the communicating
device must be changed to new PAX2 settings and this
register returns to 0.
DISPLAY SELECTION