REED 8706 Specifications

General IconGeneral
Frequency Range31.5Hz to 8kHz
Resolution (Sound)0.1dB
Microphone1/2 inch Electret Condenser microphone
Power Source9V battery
Resolution (Lux)1 Lux
TypeSound Level Meter
Measurement Range (Sound)30 dB to 130 dB
Accuracy (Sound)±1.5 dB
WeightingA/C
Response TimeFast/Slow
DisplayLCD
Measurement Range (Lux)0 to 20, 000 Lux
Accuracy (Lux)±5%

Summary

Product Features

Technical Specifications

Instrument Description and Controls

Power On/Off Button

Controls the power state of the digital psychrometer.

°C/°F Temperature Unit Selection

Allows switching between Celsius and Fahrenheit temperature units.

Measurement Mode Selection

Enables switching between different measurement modes like Dry Bulb and Dew Point.

Data Hold Functionality

Freezes the current reading on the display for later viewing.

Reset Functionality

Resets stored Min/Max memory values.

Min/Max Value Display

Displays the minimum and maximum recorded readings.

Measuring Procedures and Functions

Auto Power Off and Sleep Mode

Manages automatic power shutdown to conserve battery life.

Mode Options and Display

Details how to select measurement modes and view readings.

Data Hold Operation

Explains how to freeze displayed readings.

Dew Point Measurement

Instructions for displaying and measuring dew point temperature.

Wet Bulb Temperature Measurement

Instructions for displaying and measuring wet bulb temperature.

External Temperature Measurement

Procedure for measuring temperature using an external probe.

Min/Max Value Recording

How to record and retrieve minimum and maximum measurement values.

Calibration and Troubleshooting

Meter Calibration Procedure

Step-by-step guide to calibrate the psychrometer for accuracy.

Troubleshooting Common Issues

Guidance for resolving power, display, and error code problems.

Maintenance and Support

Battery Replacement Guide

Instructions for replacing the meter's batteries.

Product Warranty Information

Details regarding the warranty coverage and terms for the meter.

Related product manuals