EOS2 SAFETY LIGHT CURTAIN
In free protected area conditions, the Receiver provides a voltage of 24VDC on both
outputs. Therefore, the established load must be connected between the output
terminals and the 0VDC (Figure 24).
RECEIVER
RECEIVER
Max. load
400mA
Max. load
400mA
Figure 24 – Correct load connection on the outputs
Technical specifications
TECHNICAL SPECIFICATIONS EOS2 LIGHT CURTAINS
Protected height mm 160 – 1510
Resolutions mm 30 – 40 - 50 - 90
No. of beams (Multibeam Models) 2/3/4 beams
0 ÷ 4 (low)
Working range (selectable) m
3 ÷ 12 (high)
Safety outputs 2 PNP – 400mA @ 24VDC
3 ÷ 19,5 (see models tables)
Response time ms
24 ± 20%
Power supply VDC
Connections M12 (5/8 pin) connectors
Max. length of connections m 100 (50 between Master and Slave)
-10 ÷ 55°C
Operating temperature °C
Protection rating IP 65 - IP 67
Section dimensions mm
2
28 x 30
Max. consumption W 1 (Emitter) 2 (Receiver)
Light curtain lifetime 20 years
IEC 61496-1:2004
IEC 61496-2:2006
Type 2
SIL 2 IEC 61508:1998
English
SILCL 2 IEC 62061:2005
Safety level
PL d - Cat.2 ISO 13849-1
Î
If the EOS2 light curtain is used in a Master-Slave configuration, use the following
formula to calculate the total response time of the device:
t
tot
= [0,1104 * (Nr
slave1
+ Nr
master
) + 1,1044] * 2 (Master + 1 slave)
t
tot
= [0,1104 * (Nr
slave1
+ Nr
slave2
+ Nr
master
) + 1,3228] * 2 (Master +2 slave)
CAPTION
t
tot
= Total response time Nr = number of beams (of the model selected)
24 8540738 • 2nd December 2009 • Rev.2