EasyManua.ls Logo

Reflex Marine FROG-XT4 - Landing Feet & Harnesses Examination; Data Plates & Load Test Examination

Reflex Marine FROG-XT4
43 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Rev 3.1 30 | P a g e
Frog XT4 Examination Checklist continued…
Item No
Description
Comment / Serial Number/
Colour Code
Pass /
Fail
Verified
By
9.
Landing Feet
Examine the feet to ensure that they are in good condition and that they are properly
secured to the capsule. Do not go underneath an active lift.
Notes:
i.
Measure height of foot and replace if under 100 mm in height
ii.
Small (20 mm in length) cuts are acceptable but feet should be replaced
when damage greater than 20mm is present.
Foot
A
B
C
D
10.
Seat Harness Security
Visually inspect the seat harness attachment points and the harness webbing for any signs
of wear, fraying or damage. Check that attachment points are secure.
11.
Seat Harnesses (sit-in)
Sit in each seat and check fastening and unfastening of each harness, to ensure correct
operation.
1
3
2
4
12.
Inspection data plate- Check the date of the last examination/ inspection to ensure the
unit will remain in compliance with requirements for at least 6 months. Update data plate to
show visual examination has been done.
13.
Stickers Check that all of the stickers on the unit are in good condition and that none are
missing or damaged. The sticker location drawing can be found in the drawing pack.
14.
Stretcher Fittings Test fit a stretcher to ensure that all of the fittings are present and in
good condition.
15.
Load Test - On critical parts replacement, a load test must be conducted. This is to be
done by an independent test house company, nationally recognised and in accordance with
ILO 152.
16.
Post Load Test Visual Inspection If a load test is done, conduct and report a post
load test visual inspection.

Related product manuals