4.6 FROG-XT6 Inspection and Maintenance Schedules
Table 7 FROG-XT6 Inspection and Maintenance Recommendation
FROG-XT6 RECOMMENDED INSPECTION AND MAINTENANCE SCHEDULES
Usage
Category
No of Transfer
Lifts per year
Pre Use
Check
Visual
Inspection
Examination
Wire Rope
Lifting
Assembly
Replacement
Load Test
Post Load Test
Visual
Inspection
Critical Parts
Replacement
Suspension
System
Replacement
Unit
Replacement
1
Low
<100
Conducted
Prior To
Every Use
6 months
12 months
12 months
36 months
4 Years
12 years
Medium
100 - 500
6 months
12 months
12 months
24 months
3 Years
8 years
High
500 - 2000
3 months
12 months
6 months
12 months
2 Years
6 years
Very High
2000 - 5000
3 months
6 months
3 months
6 months
1 years
4 years
1
This may be extended subject to a ‘condition & service assessment’ carried out by Reflex Marine or an Approved Partner