Rev 0.2 26 | P a g e
4.9 Visual Inspection Checklist Form
Frog XT6 Visual Inspection Checklist
Avg. No of Transfers
/ Year
Original Inspection
record filed in
Comment / Serial
No./ Colour Code
Wire Rope Lifting Assembly (Critical Part) (Consumable)
The wire rope lifting assembly (including attachments) must be visually inspected by a Competent
Person.
Note: High visibility cover must be completely removed to allow inspection of steel wire rope
components. It should be replaced according to the usage of the FROG. This may be as frequently as
every 3 months. Irrespective of apparent condition the lifting assembly should be replaced at least
every 12 months.
Load Plate Safety Bolts (Critical Part) (Consumable)
Visually inspect the 4 x M16 load plate safety bolts, nuts, split pins and tamper proof seals that
connect the Load Plate to the central columns for wear or damage.
Load Plate (Critical Part)
Visually inspect in situ for any signs of wear, cracks, deformation or other damage.
Node Plate Safety Bolts (Critical Part) (Consumable)
Visually inspect the 4 x M12 node plate safety bolts, nuts, split pins and tamper proof seals that
connect the node plates to the central columns for wear or damage.
Node Plate (Critical Part)
Visually inspect in situ for any signs of wear, cracks, deformation or other damage.
Seat Base Assembly and the Recoil Dampers
Visually inspect for any wear or damage and ensure that all bolts, clevis’ and other fasteners are fully
secure. Ensure that clevis pin threads are not visible on damper rods. Check to ensure that there is
no sign of any fluid leaking onto the damper rods.