Rev 0.2 29 | P a g e
4.10 Examination Checklist Form
Frog XT6 Examination Checklist
Avg. No of Transfers / Year
Original Inspection record filed in
Comment / Serial
No./ Colour Code
Wire Rope Lifting Assembly (Critical Part) (Consumable)
Replace the wire rope lifting assembly according to the usage of the FROG. This may be as
frequently as every 3 months. Irrespective of apparent condition the lifting assembly should be
replaced at least every 12 months.
Load Plate Safety Bolts (Critical Part) (Consumable)
Remove and visually inspect the 4 safety bolts for any signs of damage or strain. Visually inspect the
4 holes in the 2 central columns for signs of damage or strain. Replace appropriate parts according
to the usage of the FROG XT or on the recommendation of a Competent Person / Inspector.
Load Plate (Critical Part)
Remove and visually inspect the main Load plate for any signs of damage or strain. Replace on the
recommendation of a Competent Person / Inspector.
Node Plate Safety Bolts (Critical Part) (Consumable)
Remove and visually inspect the 4 safety bolts for any signs of damage or strain. Visually inspect the
4 holes in the 2 central columns for signs of damage or strain. Replace appropriate parts according
to the usage of the FROG XT or on the recommendation of a Competent Person / Inspector.
Node Plate (Critical Part)
Visually inspect the Node plate for any signs of damage or strain. Replace on the recommendation of
a Competent Person / Inspector.