EasyManua.ls Logo

Reflex EEHR Series - 3 Description of the Device; Identification

Reflex EEHR Series
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Description of the device
EEHR Electric screw-in heating element 18.05.2018 English
7
3
Description of the device
The device is used for heating domestic hot water /heating circuit water in a sealed storage tank made from metal. A regulator in the form or a control
knob is used to set the required temperature for the water. The water temperature should be 60°C. It is labelled by a marking. An integrated safety
temperature limiter (STB) prevents overheating by shutting down the device at 98°C.
ATTENTION
Device damage due to limescale deposits!
At temperatures > 60°C, limescale formation on the heating elements increases greatly. Heating performance is impaired.
Avoid temperatures > 60°C.
3.1
Identification
The nameplate provides information on manufacturer, year of manufacture, part number and technical data. The nameplate is attached to the device
housing.
Information on nameplate
Meaning
XXX Reflex logo, Reflex address, CE
mark
Typ/Type Device type
Spannung/voltage Supply voltage
Druck/pressure Maximum allowable pressure
Leistung/power Capacity
Schutzart/protection class Type of protection
Kunden Art.-Nr./ costomer code Customer article number
Seriennummer/ serial number Serial number

Table of Contents