Description of the device
10
English Vacuum spray degassing28.08.2019 - Rev. B
1 “WC” make-up line nominal diameter DN 15 6
“DC” degassing line (degassed water to the facility
system), nominal diameter DN 15; DN 20 (8 m-25 m)
2 Optional add-on device (see Chapter Optional
equipment and accessories)
7 “DC” degassing line (gas-rich water from the facility
system), nominal diameter DN 15; DN 20 (8 m-25 m)
3 Device 8 Device controller
4 "PU" pump 9 "DV" degassing valve
5 "PIS" pressure transducer from the device 10 230 volt signal - external make-up request from a
pressure maintenance station
Note!
Ensure the correct connection of the device to the facility system.
For the Levelcontrol make-up variant in particular, the 230 V supply cable for the external make-up request of a
pressure maintenance station must be connected to the device.
As supplied, automatic make-up is deactivated. A manual make-up via the make-up button on the device can
be performed, see chapter
9.3 "Manual make-up" on page 24 . In operation via the Reflex Control Smart App,
this is indicated and selected as “None” under the make-up variants selection.
4.4 Scope of delivery
The scope of delivery is described in the shipping document for the initial shipment and the content is shown on the packaging.
Immediately after receipt of the goods, please check the shipment for completeness and damage. Please notify us immediately of
any transport damage.
Basic degassing equipment:
Device
3 ball valves for degassing and makeup connections
Operating manual
4.5 Optional equipment and accessories
The following optional equipment and accessories are available for this device:
Fillset for make-up with water.
Fillset with integrated backflow preventer, water meter, dirt trap, and locking mechanisms for the "WC" make-up line.
Fillset Impulse with FQIRA+ contact water meter for make-up with water.
If the Fillset Impulse with FQIRA+ contact water meter is installed in the make-up line, you can regulate the entire
make-up quantity and the soft water capacity of Fillsoft softening systems. The operational reliability of the device is
assured and prevents automatic make-up during major water loss or small leaks.
RS-485 port
Use this port to retrieve all controller data and to enable the communication with control centres or other devices.
The following interfaces can be operated via the RS-485 port:
Reflex I/O modules
Ethernet
Modbus RTU
Reflex Control Remote for remote maintenance by Reflex
Service via the Reflex Remote Portal with intuitive user
interface
Other modules upon request

Other manuals for Reflex Servitec S

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Reflex Servitec S and is the answer not in the manual?

Reflex Servitec S Specifications

General IconGeneral
BrandReflex
ModelServitec S
CategoryFan
LanguageEnglish