Stove. We have printed a copy of the contents
on the back panel.
improved. Check the label on the unit and if
the correct one.
P
L
12" WC (2.98 kpa)
11" WC (2.73 kpa)
2.9" WC (0.72 kpa)
#52 (1.61mm)
16000 BTUH (4.69 kw/h)
32000 BTUH (9.38 kw/h)
0-4500 ft/pi (0-1372m)
PROPANE GAS STOVE: Model C34-LP10
L
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Minimum input
Maximum input
Altitude
APPAREIL FONCTIONNANT AU PROPANE
CONCU POUR ETRE POELE: Modéle C34-LP10
Pression d'allimentation minimum
Pression à la tubulure d' chappement lev eé é é
Pression à la tubulure d' chappement basseé
Grandeur de l'injecteur
D bit Calorifique minimum seloné
D bit Calorifique maximum seloné
l'altitude
Model/Modele:
C34-LP10
P
L
5" WC (1.25kpa)
3.8" WC (0.94kpa)
1.1" WC (0.27kpa)
#36 (2.71mm)
16000 BTUH (4.69 kw/h)
32000 BTUH (9.38 kw/h)
0-4500 ft/pi (0-1372m)
NATURAL GAS STOVE: Model C34-NG10
L
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Minimum input
Maximum input
Altitude
APPAREIL FONCTIONNANT AU GAZ NATURAL
CONCU POUR ETRE POELE: Modéle C34-NG10
Pression d'allimentation minimum
Pression à la tubulure d' chappement lev eé é é
Pression à la tubulure d' chappement basseé
Grandeur de l'injecteur
D bit Calorifique minimum seloné
D bit Calorifique maximum seloné
l'altitude
Model/Modele:
C34-NG10
DOOR SEAL:
Please check that the door is properly sealed.
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
297
DUPLICATE SERIAL NO.
FPI Fireplace Products International Ltd.
Delta, BC, Canada
Made in Canada/
Fabrique au Canada
Minimum Clearances to Combustibles /
Degagement Minimum
De Materiaux Combustibles
A 10"/250mm
B 6"/150mm
E 1.5"/38mm
Minimum ceiling height from
top of unit:36"/914mm
Minimum plafond hauteur en
haut de l'appareil: 36"/914mm
Minimum clearance to vent 1.25“/32mm
Serial No./ No de serie
919-489
Part #: 919-489
Colour: Black on Grey except selected text is in red as per this print.
Size: Printed at 100%
Material: 2 ml silver matt polyester (DPM SMS)
Dec. 09/14: Created decal
*Printer: Continue number sequence from 918-490 - do not restart at 0
Back wall
Side wall
E
A
A
B
Back wall
Side wall
Side wall
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation
Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety
Standard, Title 24 CFR, Part 3280, in the United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations
Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where
not prohibited by local codes. See owner's manual for details. Optional Fan Kit (Part # 493-917)
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1
en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured
Home Construction and Safety Standard. Si ces normes ne sont pas pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations
Standard, ou ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles.
Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée ou mobile (É.-U.
seulement) installée à demeure si les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de renseignements. Cet appareil ne peut pas être utilisé avec
d'autres gaz sauf si une trousse de conversion certifiée est fournie.
This vented gas fireplace heater is not for use with air filters. Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
For use with glass doors certified with the appliance only Pour utilisation uniquement avec les portes en verre certifiées avec l'appareil
297
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUELS.
NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE. FOYER AU GAZ À ÉVACUATION -
4001172
Listed: VENTED GAS FIREPLACE HEATER / FOYER AU GAZ À ÉVACUATION
Certified for/Certifi e pour: CANADA and U.S.A.é
Tested to: CAN/CGA-2.17-M91(R2009)
ANSI Z21.88-2014Conforms to:
CSA 2.33-2014Certified to:
For Use Only with Barrier (Part # 493-005) Follow installation instructions. Utiliser uniquement avec l’écran ( n ° 493-005) Suivre les instructions d'installation.
ELECTRICAL SUPPLY/ALIMENTATION ELECTRIQUE:
115V_60HZ less than/moins de 2 AMP
Massachusetts.
length.
t-handle type valve.
the gas appliance is installed.