EasyManua.ls Logo

Regency P33-LP10 - Safety Label

Regency P33-LP10
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Regency
®
P33-10 Zero Clearance Direct Vent Gas Fireplace | 5
|
5
safety decal
SAFETY LABEL
This is a copy of the label that accompanies each P33-10 Zero Clearance Direct Vent Gas Fireplace. We have
printed a copy of the contents here for your review. The safety label is located on the front inside base of the
unit, visible when the bottom louver is open.
NOTE: Regency
®
units are constantly being improved. Check the label on the unit and if there is a difference,
the label on the unit is the correct one.
For the State of Massachusetts, installation
and repair must be done by a plumber or
gastter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, exible
connectors shall not exceed 36 inches in
length.
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
421
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Minimum input
Maximum input
Altitude
NATURAL GAS: Model P33-NG10
PROPANE: Model P33-LP10
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Minimum input
Maximum input
Altitude
DOOR SEAL: Please check that
the door is properly sealed
FPI Fireplace Products International Ltd.
Delta, BC, Canada
Minimum Clearances to Combustibles
Degagement Minimum De Materiaux Combustibles
0" Clearance to
combustibles from:
Top,sides, bottom and rear of unit
Mantel Clearances from Top:
(A) Min. " ( mm)10 254
Side Wall Clearance from Side
Facing
B) 7.5"(191mm)
Alcove Clearances
Max. Depth 36" (914mm)
Min. Width 48" (1219mm),
Min. Height 59“ (1499mm)
(See Instruction Manual for
Detailed Instructions)
Serial No./ No de serie
919-393
5" WC (1.25 kPa)
3" WC (0. kPa).5 87
1. "WC (0. kPa)639
# 44 DMS
100Btu/h (kW)4,0 4.1
200Btu/h (kW)0.0 5.86
0- ft/pi (0- m)4500 1372
APPAREIL FONCTIONNANTAU NATURAL GAS
CONCU POUR ETRE POELE: Modéle P33-NG10
Pression d'allimentation minimum
Pression a la tubulure d' chappement lev eééé
Pression a la tubulure d' chappement basseé
Grandeur de l'injecteur
D bit Califorique minimum seloné
D bit Caliorfique maximum seloné
l'altitude
APPAREIL FONCTIONNANT AU PROPANE
CONCU POUR ETRE POELE: Modéle P33-LP10
Pression d'allimentation minimum
Pression a la tubulure d' chappement lev eééé
Pression a la tubulure d' chappement basseé
Grandeur de l'injecteur
D bit Califorique minimum seloné
D bit Caliorfique maximum seloné
l'altitude
VENTING: Use listed Simpson Dura-Vent GS System or Regency Direct Vent System. Only for direct discharge without duct connection. This appliance
must be installed in accordance with the manufacturer's installation instructions and with local codes, if any; if not, follow the current ANSI Z223.1 in the
USA or the current CAN 1-B149 in Canada. For Manufactured Home Installation: This Direct Vent System Appliance must be installed in accordance with
the manufacturer's installation instructions and Manufactured Home Construction and Safety StandardTitle 24 CFR, Part 3280, or the current Standard
for Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240 MH Mobile Home
Standard in Canada.
VENTILATION : Système de GS de Dura-conduit de Simpson énuméré par utilisation ou circuit de mise à l'air libre direct de Regency.
Seulement pour la décharge directe sans connexion de conduit. Cet appareil \ndoit être installé selon les instructions d'installation du fabricant
et avec des codes locaux éventuels ; sinon, suivez la norme ANSI actuelle Z223.1 dans \nLes Etats-Unis ou le courant PEUVENT 1-B149 dans
le Canada. Pour l'installation à la maison manufacturée : Cet appareil direct de circuit de mise à l'air libre doit être installé selon\n les instructions
d'installation du fabricant et le titre à la maison manufacturé 24 CFR de construction et de norme de sécurité, la partie 3280, ou la norme actuelle \npour
des critères de sécurité incendie pour les installations, les sites, et les Communautés à la maison manufacturés ANSI/NFPA 501A, et avec la caravane
résidentielle de CAN/CSA Z240 MH \nNorme dans le Canada.
For Use Only with Barrier 439-005 Follow installation instructions. Utiliser uniquement avec l’écran ( n ° 439-005) Suivre les instructions d'installation.(Part #)
This vented gas fireplace heater is not for use with air filters. Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
Fan (Part # 43 -917) Option: HeatWave Kit # 946-5568
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE.
Model/Modele:
P33-NG10
Model/Modele:
P33-LP10
Made in Canada/
Fabrique au Canada
Duplicate S/N
Minimum clearance of Vent
Terminal to Outside Corner &
Inside Corner: 6"/150mm
Horizontal Terminations require
the use of the AstroCap
TM
(Part # 946-523)
11"WC (2.74 kPa)
1" WC (2. kPa)049
6.4 1.59"WC( kPa)
# 5 DMS5
1 ,500 Btu/h ( kW)4 4.24
18 0 5.28,00 Btu/h ( kW)
0-4500 ft/pi (0-1372 m)
4001172
421
NOT FOR USE WITH SOLID FUELS.
NE PAS UTILISER AVEC DES
COMBUSTIBLES SOLIDE.
Listed: VENTED GAS FIREPLACE HEATER / FOYER AU GAZ À ÉVACUATION
CANADA and U.S.A.Certified for/Certifi e pour:é
Certified to: CAN/CGA-2.17-M91(R2009)
ANSI Z21.88-20 CSA 2.33-2014 &14Tested to:
Ceiling
B
B
30"
Wall
A
A
B
B
ELECTRICAL SUPPLY/
ALIMENTATION ELECTRIQUE:
115V_60HZ less than/moins de 2 AMP

Table of Contents

Related product manuals