50
FPI P36-4 Zero Clearance Direct Vent Gas Fireplace
50
OPERATING INSTRUCTIONS
MAINTENANCE
INSTRUCTIONS
1) Always turn off the gas valve before cleaning.
For relighting, refer to lighting instructions.
Keep the burner and control compartment
clean by brushing and vacuuming at least
once a year. When cleaning the logs, use a
soft clean paint brush as the logs are fragile
and easily damaged.
2) Clean appliance and door with a damp
cloth (never when unit is hot). Never use
an abrasive cleaner. The glass should be
cleaned with a gas replace glass cleaner.
The glass should be cleaned when it
starts looking cloudy.
3) The heater is nished in a heat resistant
paint and should only be re nished with
heat resistant paint. FPI uses StoveBright
Paint - Metallic Black #6309.
4) Make a periodic check of burner for proper
position and condition. Visually check the
ame of the burner periodically, making sure
the ames are steady; not lifting or oating.
If there is a problem, call a quali ed service
person.
5) The appliance and venting system must be
inspected before use, and at least annually,
by a quali ed eld service person, to ensure
that the ow of combustion and ventilation
air is not obstructed.
Note: Never operate the appliance without
the glass properly secured in place.
6) Do not use this appliance if any part has been
under water. Immediately call a quali ed
service technician to inspect the appliance
and to replace nay part of the control system
and any gas control which has been under
water.
7) Verify operation after servicing.
GENERAL VENT
MAINTENANCE
Conduct an inspection of the venting system
semi-annually. Recommended areas to inspect
as follows:
1) Check the Venting System for corrosion in
areas that are exposed to the elements.
These will appear as rust spots or
streaks, and in extreme cases, holes.
These components should be replaced
immediately.
2) Remove the Cap, and shine a ashlight
down the Vent. Remove any bird nests, or
other foreign material.