Installation, start up and operating manual – version 5.3 Gen.10
Radio control BRICK and PAIL
Working principles of the TWIN SYSTEM
P A
P B
Relè
RX
CODICE
PRIMARIO
CODICE
AUSILIARIO
sicurezza
2
sicurezza
1
EEprom
With the auxiliary transmitter unit configuration the receiver unit
accepts two unique serial codes: the primary code and the auxiliary code
with a Hamming distance of over 3.
Once the receiver unit RxDIN has been supplied with power or after it
has received the RELEASE command, it accepts the first of the two
possible codes that are in its memory. From that moment onwards the
second code will be rejected and can not be accepted unless power to
the receiver unit (RxDIN) is cut or until it receives the RELEASE
command.
The first transmitter unit that sends the START command takes control of
the lifting machinery and will keeps exclusive control until power to it is
cut or until it receives the RELEASE command.
On being switched on the operating machine emits ONLY ONE acoustic
signal if it has accepted the primary code. If the auxiliary code has been
accepted then THREE consecutive acoustic signals will be emitted.
34 REMdevice
®
- ITALY