Why is the outside temperature sensor not detected on my REMEHA Quinta Ace 30?
- DDenise BlackAug 29, 2025
If the outside temperature sensor was expected but not detected on your REMEHA Boiler, connect the sensor or connect the sensor correctly.
Why is the outside temperature sensor not detected on my REMEHA Quinta Ace 30?
If the outside temperature sensor was expected but not detected on your REMEHA Boiler, connect the sensor or connect the sensor correctly.
Why is the Room Temperature sensor not detected on my REMEHA Quinta Ace 30 Boiler?
If the room temperature sensor was expected but not detected on your REMEHA Boiler, connect the sensor or connect the sensor correctly.
How to fix poor combustion in REMEHA Quinta Ace 30?
Poor combustion in your REMEHA Boiler can stem from several causes. Here's what to check: * Purge the gas supply to remove air if there's a configuration error. * Ensure the gas tap is properly open if there's no flame during operation. * Check the operation and setting of the gas valve unit if there's no ionization current. * Verify that the air inlet and flue gas discharge flues are not blocked. * Confirm that there is no recirculation of flue gases.
What to do if Functional device has been disconnected in REMEHA Boiler?
If a functional device has been disconnected from your REMEHA Boiler, check the wiring and connectors if the SCB is not found. If the SCB is faulty, replace it.
What causes Gas Valve Control unit communication exceeding feedback time in REMEHA Quinta Ace 30?
If the Gas Valve Control unit communication has exceeded feedback time on your REMEHA Boiler, it may be due to a communication error with the security kernel. Try restarting the boiler. If the problem persists, consider replacing the CU-GH.
What does Communication Error occured mean in REMEHA Quinta Ace 30 Boiler?
If a Communication Error occurred in your REMEHA Boiler, it could be due to a communication error with the security kernel. In this case, restart the boiler. If the problem persists, replace the CU-GH.
What should I do if Safety parameters level 2, 3, 4 are not correct or missing in REMEHA Quinta Ace 30?
If the safety parameters level 2, 3, or 4 are not correct or missing in your REMEHA Boiler, it may be due to a parameter error within the security kernel. Try restarting the boiler. If the issue persists, consider replacing the CU-GH.
What causes Gas Valve Control internal blocking in REMEHA Boiler?
If a Gas Valve Control internal blocking occurred in your REMEHA Boiler, it could be due to a Security kernel error. Try restarting the boiler. If the problem persists, replace the CU-GH.
What causes No valid data from CU to GVC received error in REMEHA Quinta Ace 30 Boiler?
If no valid data from CU to GVC is received in your REMEHA Boiler, it may be due to a communication error with the CU-GH. Restart the boiler.
What to do if Uncritical device has been disconnected in REMEHA Boiler?
If an uncritical device has been disconnected from your REMEHA Boiler, check the wiring and connectors if the SCB is not found. If the SCB is faulty, replace it.
Type | Condensing boiler |
---|---|
Model | Quinta Ace 30 |
Output | 30 kW |
Fuel Type | Natural gas / LPG |
Warranty | 2 years |
Efficiency | Up to 98% |
Safety guidelines for installers and end-users, covering gas and flue gas dangers.
Important advice and warnings for safe operation and installation.
Defines responsibilities of manufacturer, installer, and user.
Overview of the manual's purpose and content.
Lists supplementary documents available for the boiler.
Explains the meaning of symbols for warnings and information.
Overview of the Quinta Ace boiler's features and benefits.
Identifies and illustrates the key internal components of the boiler.
Explains the modular and connected e-Smart control system.
Lists the items included in the standard package for the boiler.
Mentions various accessories and optional features available for the boiler.
Details mandatory regulations and installer qualifications for safe installation.
Guidelines for selecting an appropriate and safe installation site for the boiler.
Specifies requirements for connecting the boiler to the water system.
Outlines mandatory requirements for connecting the boiler to the gas supply.
Details requirements for the flue gas discharge system, including classification.
Specifies mandatory requirements for safe electrical connections.
Defines requirements for heating water quality and necessary treatment.
Discusses considerations for using the boiler in industrial process heat applications.
Explains when and how to adjust the default temperature difference setting.
Provides specific guidance for installations using open-vented systems.
Step-by-step instructions for correctly mounting the boiler on the wall.
Details how to connect the boiler to the heating and water circuits.
Instructions for safely connecting the boiler to the gas supply.
Guidance on correctly connecting the air supply and flue gas outlet.
Information and safety precautions for making electrical connections.
A comprehensive checklist of tasks to perform before starting boiler commissioning.
Explains the components, home screen, and menus of the control panel.
The overall steps required to commission the boiler and its system.
Procedures for adjusting gas settings, including factory defaults and different gas types.
Concluding checks and final steps after the commissioning process.
Explains the system of parameter codes used for configuring settings.
How to navigate and search for specific settings and data points.
Provides lists of parameters for the CU-GH08 control unit.
General rules and important notes for performing boiler maintenance.
Explains how the boiler indicates when service is required.
Step-by-step guide on how to safely open the boiler casing for access.
Outlines routine checks and maintenance tasks for the boiler.
Concluding steps after maintenance, including checks and system restart.
Introduction to error codes displayed by the control unit and their types.
How to read out and clear the boiler's error history log.
Step-by-step guide for starting the boiler for the first time.
How to navigate through user-level menus on the control panel.
Description of the main screen and its navigation.
How to set up holiday mode to reduce temperatures and save energy.
Options for configuring individual heating circuits and zones.
How to adjust room temperature settings for specific zones.
How to configure and adjust domestic hot water settings.
How to enable or disable the central heating function to save energy.
How to activate/deactivate summer mode for energy saving.
How to select the overall operating mode of the appliance.
How to adjust settings related to the control panel's display and functions.
Procedures for safely shutting down the boiler.
Information on the boiler's frost protection features and limitations.
Details about certifications and approvals for the boiler.
Provides a detailed wiring diagram of the boiler's electrical components.
Shows the physical dimensions and connection points of the boiler.
Presents comprehensive technical data, including outputs, efficiencies, and gas consumption.
Information and guidance on selecting and installing a boiler pump.
Information related to the Energy-related Products Directive, including product fiche.
Statement of the appliance's compliance with European directives.