What does Configuration Error mean in REMEHA Quinta Ace 30?
- MmadisonsuttonSep 3, 2025
If your REMEHA Boiler is showing a Configuration Error, it may be due to a configuration error or an unknown configuration number. Reset CN1 and CN2.
What does Configuration Error mean in REMEHA Quinta Ace 30?
If your REMEHA Boiler is showing a Configuration Error, it may be due to a configuration error or an unknown configuration number. Reset CN1 and CN2.
What to do if the Return temperature difference is too large in REMEHA Boiler?
A large return temperature difference in your REMEHA Boiler can be caused by: * Air in the central heating system: Vent the system to remove air. * Water pressure issues: Check the water pressure. * Incorrect boiler type parameter setting: Verify the setting. * Circulation problems: Check the direction, pump, and valves. * Heating pump malfunction: Ensure the pump is operating correctly. * Heat exchanger cleanliness: Inspect and clean the heat exchanger if necessary. * Sensor issues: Check the operation and fitting of the sensors. Replace the sensor if necessary.
Why does my REMEHA Quinta Ace 30 show a 5x Error of unintended Flame Loss occurrence?
If your REMEHA Boiler shows a 5x Error of unintended Flame Loss occurrence, it could be due to: * Low ionization current: Vent the gas supply to remove air. * Gas valve issues: Ensure the gas valve is fully opened and check its operation and setting. * Gas supply problems: Check the gas supply pressure. * Blockages: Verify that the air supply inlet and flue gas outlet are not blocked. * Flue gas recirculation: Ensure there is no recirculation of flue gases.
What causes maximum heat exchanger temperature increase exceeded in REMEHA Quinta Ace 30 Boiler?
If the maximum heat exchanger temperature increase has been exceeded in your REMEHA Boiler, check the circulation (direction, pump, valves) and the water pressure. Also, check the cleanliness of the heat exchanger. Ensure that the sensors are operating correctly and that the sensor has been fitted properly.
What does deviation in flow sensor 1 and flow sensor 2 detected mean for REMEHA Quinta Ace 30 Boiler?
If a deviation in flow sensor 1 and flow sensor 2 is detected in your REMEHA Boiler due to flow temperature sensor deviation, check the connection. Also, replace the sensor if it's faulty.
What to do if The time reserved for the shower has elapsed in REMEHA Quinta Ace 30?
If the time reserved for the shower has elapsed on your REMEHA Boiler, take a shorter shower or adjust parameter DP357.
What does Communication Error occured mean in REMEHA Quinta Ace 30 Boiler?
If a Communication Error occurred in your REMEHA Boiler, it could be due to a communication error with the security kernel. In this case, restart the boiler. If the problem persists, replace the CU-GH.
What should I do if Safety parameters level 2, 3, 4 are not correct or missing in REMEHA Quinta Ace 30?
If the safety parameters level 2, 3, or 4 are not correct or missing in your REMEHA Boiler, it may be due to a parameter error within the security kernel. Try restarting the boiler. If the issue persists, consider replacing the CU-GH.
What to do if return temperature sensor is either shorted or measures a temperature above range in REMEHA Quinta Ace 30 Boiler?
If the return temperature sensor is either shorted or measures a temperature above range on your REMEHA Boiler, check the wiring and connectors if the return temperature sensor is short-circuited. Also, check that the sensor has been correctly fitted if it was incorrectly fitted and replace the sensor if it's faulty.
Why is the return temperature sensor not detected in my REMEHA Quinta Ace 30?
If the return temperature sensor was expected but not detected on your REMEHA Boiler, check the wiring and connectors. Also, consider replacing the sensor.
Type | Condensing boiler |
---|---|
Model | Quinta Ace 30 |
Output | 30 kW |
Fuel Type | Natural gas / LPG |
Warranty | 2 years |
Efficiency | Up to 98% |
Safety guidelines for installers and end-users, covering gas and flue gas dangers.
Important advice and warnings for safe operation and installation.
Defines responsibilities of manufacturer, installer, and user.
Overview of the manual's purpose and content.
Lists supplementary documents available for the boiler.
Explains the meaning of symbols for warnings and information.
Overview of the Quinta Ace boiler's features and benefits.
Identifies and illustrates the key internal components of the boiler.
Explains the modular and connected e-Smart control system.
Lists the items included in the standard package for the boiler.
Mentions various accessories and optional features available for the boiler.
Details mandatory regulations and installer qualifications for safe installation.
Guidelines for selecting an appropriate and safe installation site for the boiler.
Specifies requirements for connecting the boiler to the water system.
Outlines mandatory requirements for connecting the boiler to the gas supply.
Details requirements for the flue gas discharge system, including classification.
Specifies mandatory requirements for safe electrical connections.
Defines requirements for heating water quality and necessary treatment.
Discusses considerations for using the boiler in industrial process heat applications.
Explains when and how to adjust the default temperature difference setting.
Provides specific guidance for installations using open-vented systems.
Step-by-step instructions for correctly mounting the boiler on the wall.
Details how to connect the boiler to the heating and water circuits.
Instructions for safely connecting the boiler to the gas supply.
Guidance on correctly connecting the air supply and flue gas outlet.
Information and safety precautions for making electrical connections.
A comprehensive checklist of tasks to perform before starting boiler commissioning.
Explains the components, home screen, and menus of the control panel.
The overall steps required to commission the boiler and its system.
Procedures for adjusting gas settings, including factory defaults and different gas types.
Concluding checks and final steps after the commissioning process.
Explains the system of parameter codes used for configuring settings.
How to navigate and search for specific settings and data points.
Provides lists of parameters for the CU-GH08 control unit.
General rules and important notes for performing boiler maintenance.
Explains how the boiler indicates when service is required.
Step-by-step guide on how to safely open the boiler casing for access.
Outlines routine checks and maintenance tasks for the boiler.
Concluding steps after maintenance, including checks and system restart.
Introduction to error codes displayed by the control unit and their types.
How to read out and clear the boiler's error history log.
Step-by-step guide for starting the boiler for the first time.
How to navigate through user-level menus on the control panel.
Description of the main screen and its navigation.
How to set up holiday mode to reduce temperatures and save energy.
Options for configuring individual heating circuits and zones.
How to adjust room temperature settings for specific zones.
How to configure and adjust domestic hot water settings.
How to enable or disable the central heating function to save energy.
How to activate/deactivate summer mode for energy saving.
How to select the overall operating mode of the appliance.
How to adjust settings related to the control panel's display and functions.
Procedures for safely shutting down the boiler.
Information on the boiler's frost protection features and limitations.
Details about certifications and approvals for the boiler.
Provides a detailed wiring diagram of the boiler's electrical components.
Shows the physical dimensions and connection points of the boiler.
Presents comprehensive technical data, including outputs, efficiencies, and gas consumption.
Information and guidance on selecting and installing a boiler pump.
Information related to the Energy-related Products Directive, including product fiche.
Statement of the appliance's compliance with European directives.