  • C
    Cassandra SwansonSep 3, 2025
    What does Configuration Error mean in REMEHA Boiler?
    • K
      Kimberly ReyesSep 3, 2025
      If your REMEHA Boiler is showing a Configuration Error, it may be due to a configuration error or an unknown configuration number. Reset CN1 and CN2.
  • D
    Dr. Pamela Parks MDAug 25, 2025
    What to do if the Return temperature difference is too large in REMEHA Quinta Ace 90 Boiler?
    • P
      Patricia BrooksAug 25, 2025
      A large return temperature difference in your REMEHA Boiler can be caused by: * Air in the central heating system: Vent the system to remove air. * Water pressure issues: Check the water pressure. * Incorrect boiler type parameter setting: Verify the setting. * Circulation problems: Check the direction, pump, and valves. * Heating pump malfunction: Ensure the pump is operating correctly. * Heat exchanger cleanliness: Inspect and clean the heat exchanger if necessary. * Sensor issues: Check the operation and fitting of the sensors. Replace the sensor if necessary.
  • M
    Michele MeyerAug 25, 2025
    Why does my REMEHA Quinta Ace 90 Boiler show a 5x Error of unintended Flame Loss occurrence?
    • D
      Daniel AdamsAug 26, 2025
      If your REMEHA Boiler shows a 5x Error of unintended Flame Loss occurrence, it could be due to: * Low ionization current: Vent the gas supply to remove air. * Gas valve issues: Ensure the gas valve is fully opened and check its operation and setting. * Gas supply problems: Check the gas supply pressure. * Blockages: Verify that the air supply inlet and flue gas outlet are not blocked. * Flue gas recirculation: Ensure there is no recirculation of flue gases.
  • A
    Andrew YoungSep 9, 2025
    What causes maximum heat exchanger temperature increase exceeded in REMEHA Quinta Ace 90?
    • A
      Alexis AllenSep 9, 2025
      If the maximum heat exchanger temperature increase has been exceeded in your REMEHA Boiler, check the circulation (direction, pump, valves) and the water pressure. Also, check the cleanliness of the heat exchanger. Ensure that the sensors are operating correctly and that the sensor has been fitted properly.
  • K
    Keith VasquezSep 16, 2025
    Why water pressure sensor was expected but not detected in REMEHA Quinta Ace 90 Boiler?
    • D
      Don MelendezSep 16, 2025
      If the water pressure sensor was expected but not detected on your REMEHA Boiler, connect the sensor if the water pressure sensor is not connected or connect the sensor correctly if it is not connected correctly.
  • C
    Cathy SchneiderSep 6, 2025
    What to do if The time reserved for the shower has elapsed in REMEHA Quinta Ace 90 Boiler?
    • J
      James KellySep 6, 2025
      If the time reserved for the shower has elapsed on your REMEHA Boiler, take a shorter shower or adjust parameter DP357.
  • D
    Donald OnealAug 31, 2025
    What does Communication Error occured mean in REMEHA Boiler?
    • S
      Stefanie WrightAug 31, 2025
      If a Communication Error occurred in your REMEHA Boiler, it could be due to a communication error with the security kernel. In this case, restart the boiler. If the problem persists, replace the CU-GH.
  • J
    Javier BartlettSep 22, 2025
    What to do if gas valve control internal locking in REMEHA Boiler?
    • H
      hector30Sep 22, 2025
      If there is a Gas Valve Control internal locking on your REMEHA Boiler, restart the boiler or replace the CU-GH.
  • L
    Lisa DavidSep 13, 2025
    What to do if return temperature sensor is either shorted or measures a temperature above range in REMEHA Quinta Ace 90 Boiler?
    • S
      Shelley HobbsSep 13, 2025
      If the return temperature sensor is either shorted or measures a temperature above range on your REMEHA Boiler, check the wiring and connectors if the return temperature sensor is short-circuited. Also, check that the sensor has been correctly fitted if it was incorrectly fitted and replace the sensor if it's faulty.
  • C
    Christopher HardinAug 27, 2025
    Why is the return temperature sensor not detected in my REMEHA Quinta Ace 90?
    • F
      fosterjoyAug 27, 2025
      If the return temperature sensor was expected but not detected on your REMEHA Boiler, check the wiring and connectors. Also, consider replacing the sensor.

Summary

Product Description

3.3 Control Panel Description

Details the components and functions of the boiler's control panel, including buttons and display.

User Instructions

5.2 Heating Circuit Configuration

Instructions for setting up and customizing heating circuit parameters.

5.3 Domestic Hot Water Settings

Details on configuring domestic hot water temperature and modes.

Installer Instructions

6.3 Configuration and Parameters

Details on configuring appliance parameters, heating curves, and screed drying programs.

6.4 Commissioning and Load Testing

Steps for commissioning the appliance, including chimney sweep and load tests.

6.6 Resetting and Restoring Settings

Instructions for updating firmware, resetting, and restoring configuration settings.

Settings

7.1 Parameter Adjustment

Instructions on how to change appliance parameters for optimal performance.

Operation

Maintenance

9.3 Inspection and Combustion Checks

Procedures for checking water pressure, ionisation, connections, and combustion analysis.

9.4 Component Servicing and Reassembly

Guides on cleaning siphon, components, checking non-return valve, and boiler reassembly.

Troubleshooting

10.1 Error Codes and Solutions

Details on error code levels (Warning, Blocking, Lock out) with causes and solutions.