Installation and User Manual
High-efficiency wall-hung gas boiler
Quinta Ace
30 - 45 - 55 - 65 - 90 - 115
HMI T-control

Table of Contents

Other manuals for REMEHA Quinta Ace 115

Questions and Answers

  • T
    theresa11Sep 3, 2025
    What does Configuration Error mean in REMEHA Quinta Ace 115?
    • C
      Christopher CarterSep 3, 2025
      If your REMEHA Boiler is showing a Configuration Error, it may be due to a configuration error or an unknown configuration number. Reset CN1 and CN2.
  • A
    andrew16Aug 25, 2025
    What to do if the Return temperature difference is too large in REMEHA Boiler?
    • M
      Michael WaltersAug 25, 2025
      A large return temperature difference in your REMEHA Boiler can be caused by: * Air in the central heating system: Vent the system to remove air. * Water pressure issues: Check the water pressure. * Incorrect boiler type parameter setting: Verify the setting. * Circulation problems: Check the direction, pump, and valves. * Heating pump malfunction: Ensure the pump is operating correctly. * Heat exchanger cleanliness: Inspect and clean the heat exchanger if necessary. * Sensor issues: Check the operation and fitting of the sensors. Replace the sensor if necessary.
  • D
    derrick67Aug 25, 2025
    Why does my REMEHA Quinta Ace 115 show a 5x Error of unintended Flame Loss occurrence?
    • A
      Ashley VillaAug 26, 2025
      If your REMEHA Boiler shows a 5x Error of unintended Flame Loss occurrence, it could be due to: * Low ionization current: Vent the gas supply to remove air. * Gas valve issues: Ensure the gas valve is fully opened and check its operation and setting. * Gas supply problems: Check the gas supply pressure. * Blockages: Verify that the air supply inlet and flue gas outlet are not blocked. * Flue gas recirculation: Ensure there is no recirculation of flue gases.
  • J
    Joseph BeanSep 9, 2025
    What causes maximum heat exchanger temperature increase exceeded in REMEHA Boiler?
    • A
      Amber DaySep 9, 2025
      If the maximum heat exchanger temperature increase has been exceeded in your REMEHA Boiler, check the circulation (direction, pump, valves) and the water pressure. Also, check the cleanliness of the heat exchanger. Ensure that the sensors are operating correctly and that the sensor has been fitted properly.
  • J
    josehoSep 16, 2025
    Why water pressure sensor was expected but not detected in REMEHA Quinta Ace 115?
    • S
      Scott DelgadoSep 16, 2025
      If the water pressure sensor was expected but not detected on your REMEHA Boiler, connect the sensor if the water pressure sensor is not connected or connect the sensor correctly if it is not connected correctly.
  • B
    belljoanSep 6, 2025
    What to do if The time reserved for the shower has elapsed in REMEHA Boiler?
    • J
      Julie WarrenSep 6, 2025
      If the time reserved for the shower has elapsed on your REMEHA Boiler, take a shorter shower or adjust parameter DP357.
  • A
    Anita HallAug 31, 2025
    What does Communication Error occured mean in REMEHA Boiler?
    • J
      James WebbAug 31, 2025
      If a Communication Error occurred in your REMEHA Boiler, it could be due to a communication error with the security kernel. In this case, restart the boiler. If the problem persists, replace the CU-GH.
  • T
    Theresa WestSep 22, 2025
    What to do if gas valve control internal locking in REMEHA Boiler?
    • J
      jamesturnerSep 22, 2025
      If there is a Gas Valve Control internal locking on your REMEHA Boiler, restart the boiler or replace the CU-GH.
  • R
    Regina MartinezSep 13, 2025
    What to do if return temperature sensor is either shorted or measures a temperature above range in REMEHA Quinta Ace 115 Boiler?
    • R
      Roy GriffinSep 13, 2025
      If the return temperature sensor is either shorted or measures a temperature above range on your REMEHA Boiler, check the wiring and connectors if the return temperature sensor is short-circuited. Also, check that the sensor has been correctly fitted if it was incorrectly fitted and replace the sensor if it's faulty.
  • S
    Steven ThompsonAug 27, 2025
    Why is the return temperature sensor not detected in my REMEHA Quinta Ace 115 Boiler?
    • M
      Megan JohnsonAug 27, 2025
      If the return temperature sensor was expected but not detected on your REMEHA Boiler, check the wiring and connectors. Also, consider replacing the sensor.

Summary

Safety and General Information

General Safety Instructions

Safety guidelines for installers and end-users regarding gas and flue gas.

Installation Preparation

Regulations and Location Choice

Guidelines for selecting installation location and adhering to regulations.

Water, Gas, and Flue Gas Requirements

Specifies requirements for connecting water, gas, and flue gas systems.

Boiler Installation Procedures

Gas, Flue Gas, and Air Supply Connections

Procedures for connecting gas, flue gas, and air supply components.

Commissioning and Settings

Commissioning Procedure and Gas Settings

Steps for initial boiler commissioning, including gas settings and adjustments.

Maintenance Procedures

Troubleshooting and Error Handling

Error Codes and Warnings

Explains different types of error codes, warnings, and their meanings.

Technical Specifications

REMEHA Quinta Ace 115 Specifications

General IconGeneral
ModelQuinta Ace 115
CategoryBoiler
Output115 kW
Fuel TypeNatural Gas
Installation TypeWall-mounted