Why is the outside temperature sensor not detected on my REMEHA Quinta Ace 65?
- Cchristopher08Aug 29, 2025
If the outside temperature sensor was expected but not detected on your REMEHA Boiler, connect the sensor or connect the sensor correctly.
Why is the outside temperature sensor not detected on my REMEHA Quinta Ace 65?
If the outside temperature sensor was expected but not detected on your REMEHA Boiler, connect the sensor or connect the sensor correctly.
Why is the Room Temperature sensor not detected on my REMEHA Quinta Ace 65 Boiler?
If the room temperature sensor was expected but not detected on your REMEHA Boiler, connect the sensor or connect the sensor correctly.
Why is the Water pressure sensor not detected on my REMEHA Quinta Ace 65 Boiler?
If the water pressure sensor was expected but not detected on your REMEHA Boiler, connect the sensor or connect the sensor correctly.
What to do if Functional device has been disconnected in REMEHA Quinta Ace 65?
If a functional device has been disconnected from your REMEHA Boiler, check the wiring and connectors if the SCB is not found. If the SCB is faulty, replace it.
What causes Gas Valve Control unit communication exceeding feedback time in REMEHA Quinta Ace 65 Boiler?
If the Gas Valve Control unit communication has exceeded feedback time on your REMEHA Boiler, it may be due to a communication error with the security kernel. Try restarting the boiler. If the problem persists, consider replacing the CU-GH.
What does Communication Error occured mean in REMEHA Boiler?
If a Communication Error occurred in your REMEHA Boiler, it could be due to a communication error with the security kernel. In this case, restart the boiler. If the problem persists, replace the CU-GH.
What should I do if Safety parameters level 2, 3, 4 are not correct or missing in REMEHA Quinta Ace 65?
If the safety parameters level 2, 3, or 4 are not correct or missing in your REMEHA Boiler, it may be due to a parameter error within the security kernel. Try restarting the boiler. If the issue persists, consider replacing the CU-GH.
What causes Gas Valve Control internal blocking in REMEHA Quinta Ace 65?
If a Gas Valve Control internal blocking occurred in your REMEHA Boiler, it could be due to a Security kernel error. Try restarting the boiler. If the problem persists, replace the CU-GH.
What causes No valid data from CU to GVC received error in REMEHA Quinta Ace 65 Boiler?
If no valid data from CU to GVC is received in your REMEHA Boiler, it may be due to a communication error with the CU-GH. Restart the boiler.
What to do if Uncritical device has been disconnected in REMEHA Quinta Ace 65 Boiler?
If an uncritical device has been disconnected from your REMEHA Boiler, check the wiring and connectors if the SCB is not found. If the SCB is faulty, replace it.
Model | Quinta Ace 65 |
---|---|
Category | Condensing Boiler |
Fuel Type | Natural Gas / LPG |
Output Power | 65 kW |
Max Heat Output (80/60°C) | 65 kW |
Installation | Wall-mounted |
Modulation Range | 1:5 |
Max Working Pressure | 3 bar |
Max Flow Temperature | 85°C |
Electrical Connection | 230V, 50Hz |
Protection Rating | IPX4D |
Type | Condensing |
Essential safety guidelines for installers and end-users.
Mandatory regulations for boiler installation compliance.
Guidance on selecting the optimal installation site.
Covers all aspects of electrical connections.
Essential steps before starting commissioning.
The overall process for initial boiler commissioning.
Configuration of gas parameters for optimal operation.
Procedure for adapting the boiler to various gas types.
Ensuring correct gas-air mixture for combustion.
Rules and requirements for performing maintenance.
Routine checks and maintenance tasks.
Explanation of error codes displayed by the control panel.
Details on warning messages and their solutions.
Information on blocking errors and how to address them.
Details on locking errors and their resolution steps.
Comprehensive table of technical performance data.