How to troubleshoot blocking input in locked-out mode on REMEHA Quinta Pro Boiler?
- LLogan BrewerSep 8, 2025
If the blocking input is in locked-out mode in your REMEHA Boiler, check the wiring, remove any external causes, and check the parameters.
How to troubleshoot blocking input in locked-out mode on REMEHA Quinta Pro Boiler?
If the blocking input is in locked-out mode in your REMEHA Boiler, check the wiring, remove any external causes, and check the parameters.
How do I fix a communication error with the SU PCB on my REMEHA Boiler?
If there is a communication error with the SU PCB in your REMEHA Boiler, check whether the SU PCB has been correctly fitted in the connector on the PCU PCB.
What to do if my REMEHA Quinta Pro shows 'no release signal'?
If there is no release signal in your REMEHA Boiler, remove any external causes, check the parameters, and inspect the wiring.
What should I do if there's a fan operation error in my REMEHA Quinta Pro?
If the fan is not operating correctly in your REMEHA Boiler, check the wiring. Replace the fan if necessary and check for adequate draw on the chimney connection.
Type | Condensing Boiler |
---|---|
Installation | Wall-mounted |
Heat Exchanger Material | Stainless Steel |
Fuel Type | Natural Gas, Propane |
Control | Compatible with various BMS systems |
Warranty | 5-year limited warranty (heat exchanger) |
Essential safety guidelines for installers and users regarding gas and flue gas.
Advice on safe operation, installation, maintenance, and handling.
Outlines responsibilities of manufacturer, installer, and user regarding product use and maintenance.
Explains the meaning of symbols used to denote danger levels.
Lists and defines abbreviations used in the manual.
Details certifications, NOx class, and connection types for the boiler.
Presents key technical specifications like output, efficiency, and gas data.
Provides physical dimensions and port configurations for installation.
Illustrates the boiler's electrical wiring and component layout.
Outlines the Quinta Pro boiler's key properties and features.
Explains how the boiler functions, including pump and water flow.
Identifies and illustrates the main internal components of the boiler.
Details the function of control panel keys and display symbols.
Lists the items included in the standard boiler package.
Mentions available optional accessories for the boiler.
Specifies mandatory regulations and installer qualifications for installation.
Provides guidelines for selecting a suitable installation site for the boiler.
Describes the information found on the boiler's type plate.
Details requirements for the boiler's physical placement and installation space.
Outlines ventilation standards and compliance requirements.
States that installation must be done by qualified installers according to regulations.
Covers the initial steps for preparing the boiler and wall for mounting.
Details how to mount the boiler using the provided bracket and template.
Guides on connecting the boiler to the central heating and DHW systems.
Emphasizes the importance of cleaning and flushing the system before connection.
Step-by-step instructions for connecting the flow and return pipes.
Details on how to connect the expansion vessel to the system.
Instructions for correctly connecting the condensate drain.
Provides instructions for safely connecting the gas supply to the boiler.
Introduces flue gas connection types and classifications.
Details different flue gas connection types (e.g., C13, C33).
Lists manufacturers for drain systems and discusses outlet kits.
Provides guidelines on maximum chimney lengths and pipe reductions.
Offers further advice on installing flue gas and air supply materials.
Details assembly steps for flue gas and air supply connections.
Covers all aspects of electrical connections, from control units to optional PCBs.
Provides important connection values for the control unit.
Gives recommendations for making electrical connections safely and correctly.
Explains how to access and connect various components to the PCB.
Details how to connect the PWM pump to the standard PCB.
Discusses the PCBs installed and connection options for the 0-10 V PCB.
Details connections for external CH pump, three-way valve, and gas pressure switch.
Explains configuring rotary knobs for status messages on SCU-X01 PCB.
Provides instructions for filling the boiler and central heating system with water.
Advises on water quality and treatment for the heating system.
Details the procedure for dismantling, cleaning, and refitting the siphon.
Guides on filling the central heating system and checking for leaks.
Outlines steps to put the boiler into operation.
Details checks and procedures for the gas circuit.
Covers checks for the hydraulic circuit, including siphon and water connections.
Guides on checking electrical connections before commissioning.
Step-by-step guide for the initial commissioning of the boiler.
Covers gas settings, including adaptation to different gas types.
Instructions for adjusting the boiler for different gas types.
Details how to measure and adjust the O2/CO2 levels for optimal combustion.
Concludes commissioning with final checks and user instruction.
Explains how to use the control panel and interpret its displays.
Provides instructions for safely shutting down the boiler.
Details how the boiler's frost protection works and how to set it.
Lists and describes various parameters and their factory settings.
Guides on how to optimize boiler operation by adjusting parameters.
Guides on how users can modify parameters at the user level.
Details how installers can change parameters using an access code.
Explains how to set the maximum heat output for central heating.
Describes the process to reset the boiler to its original factory settings.
Explains the procedure for performing an auto-detect after PCB replacement.
Guides on how to set the boiler to manual operating mode.
Explains how to read current operational values from the control panel.
Details how to access and view various real-time boiler parameters.
Shows how to retrieve boiler operating hours and start success rates.
Lists and explains the various status and sub-status codes displayed by the boiler.
States that the boiler requires periodic inspection and maintenance.
Explains the automatic service message system for preventive maintenance.
Guides on how to reset the service message after maintenance.
Details how to initiate a new service interval for the boiler.
Lists routine inspection and maintenance tasks.
Describes how to check and maintain the correct water pressure in the system.
Explains how to check the ionisation current for burner operation.
Guides on checking flue gas and air supply connections for condition and tightness.
Details how to check combustion by measuring O2/CO2 in flue gases.
Instructions for checking the automatic air vent for leaks or proper function.
Details the procedure for dismantling, cleaning, and refitting the siphon.
Guides on checking the burner and cleaning the heat exchanger.
Covers specific maintenance tasks that may be required.
Provides instructions for replacing the ionisation/ignition electrode.
Details how to inspect and replace the non-return valve if defective.
Step-by-step guide for reassembling the boiler after maintenance.
Lists and explains error codes displayed by the boiler.
Explains boiler blocking modes and how to read blocking codes.
Describes boiler lockout states and how to interpret error codes.
Explains how the boiler stores and manages error history.
Guides on how to access and view stored error codes and related data.
Details the procedure for clearing error codes from the boiler's memory.
Provides step-by-step instructions for safely removing and disposing of the boiler.
Emphasizes using only original or recommended spare parts for replacements.
Illustrates and lists the spare parts for Quinta Pro 30-45 models.
Presents ErP information including energy efficiency class and heat output.
Provides key product data as per the ErP directive.
Details how to calculate the seasonal space heating energy efficiency of a package.
States compliance with European directives and availability of declaration.
Lists optional PCBs that can be purchased and installed.
Explains how to access the PCB housing for installing optional PCBs.
Details connections for gas pressure switch and heat recovery unit on SCU-S03.
Explains connecting 230 VAC or 24 VAC three-way valves to SCU-X02.
Describes controlling a modulating central heating pump via SCU-X03 PCB.
Mentions connection options for c-Mix PCB for heating groups and calorifiers.