AUTOMATIC TRANSMISSION
Multifunction switch
23
TIGHTENING TORQUES (in daN.m)
Multifunction switch mounting bolt 1
Lever mounting nut 1
REMOVAL
Place the switch in position D.
Remove the air intake pipe.
Disconnect the ball joint from the multifunction
switch selection cable.
Remove:
- the lever and the two multifunction switch
mounting bolts,
- the three modular connector (3) support plate
mounting bolts (1).
- the modular connector plate mounting bolts
then extract the connector from the
multifunction switch (12-way)
14829R1
REFITTING
Place the multifunction switch in position D.
Reconnect the multifunction switch connector.
13785R
14852M
23-16