67
Operation
Program
Code
Description Parameter Setting Boost Voltage Float Voltage
For accurate
charging,
connection to
a temperature
VHQVRULVUHTXLUHG
Sealed Lead Acid
14.4V 13.6V
Gel 2
14.4V 13.8V
Open Lead Acid / Flooded
14.8V 13.8V
Calcium
15.1V 13.6V
De-sulphation
15.5V for 4 hours
LI
When the voltage reaches
14.2V, the charging will stop.
NOT
E
z
The voltage of lithium charging is preset to 14.7V. When the charging voltage reaches the
preset threshold 14.7V, the inverter charger stops charging. It resumes charging when the
FKDUJLQJYROWDJHGURSVEHORZ9
z
,IWKHSUHVHWEDWWHU\SDUDPHWHUVDUHQRWFRPSDWLEOHZLWK\RXUV\VWHP\RXFDQVHWWKHEDWWHU\
W\SHWREWRHQWHUWKH8VHUPRGH<RXFDQDOVRXVHWKH'&+RPHDSSWRFXVWRPL]HWKH
parameters. For details, see User ModeEHORZ
LCD Button Setting Battery Type User Mode