Adjustment channels
Channel Description Factory setting Page
BHMN s Thermostat comfort temperature 40 °C [110 °F] 28
BH O s Switch-on temperature for thermostat 40 °C [110 °F] 28
BH F s Switch-off temperature for thermostat 45 °C [120 °F] 28
t1 O s Thermostat switch-on time 1 00:00 28
t1 F s Thermostat switch-off time 1 00:00 28
t2 O s Thermostat switch-on time 2 00:00 28
t2 F s Thermostat switch-off time 2 00:00 28
t3 O s Thermostat switch-on time 3 00:00 28
t3 F s Thermostat switch-off time 3 00:00 28
BOOS s Rapid heat-up runtime 90 min 29
ODB x Drainback option OFF 29
tDTO x* ODB switch-on condition - time period 60 s 30
tFLL x* ODB lling time 5.0 min 30
tSTB x* ODB stabilisation time 2.0 min 30
OTD s Thermal disinfection option OFF 30
PDIS s* Monitoring period 01:00 30
DDIS s* Disinfection period 01:00 30
TDIS s* Disinfection temperature 60 °C [140 °F] 30
SDIS s* Starting time 00:00 31
MAN1 x Manual mode R1 On 31
MAN2 x Manual mode R2 OFF 31
LANG x Language dE 32
UNIT x Temperature unit °C 32
RESE x Reset - back to factory settings 32
######## Version number
Symbol Description
x Channel is available
x* Channel is available, if the corresponding option is activated.
s System-specic channel
s* System-specic channel, only available if the corresponding option is activated