The controller (1) compares the temperature measured by
sensor S1 at the buffer store (2) with the reverse tem-
perature at measuring sensor S2. If the measured tem-
perature difference is higher or identical to the adjusted
6.3 Reverse raising of the heating circuit:
value ΔT, the reverse temperature is increased by the
warmth of the buffer store when connecting the 3-way-
valve (3)(heating support) .
The controller (1) compares the temperatures measured
by sensor S1 in the boiler or chimney boiler (2) with the
temperature measured by sensor S2 in the store (3). If the
measured temperature difference is higher or identical to
the adjusted value DO (switch-on temperature difference),
the pump (4) is activated, if the adjusted minimum
temperature (CN, adjustment range 10,1 ...90 °C) is
simultaneously reached or exceeded. If the switch-off
6.4 Loading of the store by solid fuel boiler or chimney boiler:
temperature difference DF or the minimum temperature is
underrun, the pump switches-off.
Necessary adjustment for minimum temperature limitation
(to avoid flue gas condensation):
CN = 60 °C (recommended)