EasyManuals Logo

Resol DeltaSol BX User Manual

Resol DeltaSol BX
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #65 background imageLoading...
Page #65 background image
en
65
InstallationIndications, functions and optionsMessages Commissioning Operation and function
19
PRS 17
PUSH
OLEAK
Low pressure monitoring option
Adjustment range: OFF / ON
Factory setting: OFF
LEAKO
On at
Adjustment range: 0.3 5.7 bar
Factory setting: 0.7 bar
LEAKF
Off at
Adjustment range: 0.6 6.0 bar
Factory setting: 1.0 bar
DATE 18
PUSH
TIME
Time
Adjustment range: 00:00 … 23:59
Factory setting: 12:00
MM
Month
Adjustment range: 01 … 12
Factory setting: 03
YYYY
Year
Adjustment range: 2010 … 2099
Factory setting: 2010
DD
Day
Adjustment range: 01 … 31
Factory setting: 15
18
Time and date
The controller is equipped with a real time clock required e. g. for the thermostat
function.
18
17
Low pressure (leakage)
If the system pressure falls below the adjustable switch-on value, an error message
will appear.
When the pressure reaches or exceeds the adjustable switch-off value, the mes-
sage disappears.
Note:
For the Low pressure monitoring function, the switch-off value has to
be adjusted at least 0.1 bar higher than the switch-on value. The adjust-
ment ranges will automatically adapt to that.