IKONIC Tankless Water Heater Service Manual
15
GENERAL INFORMATION
1.3 DIAGNOSTIC POINTS ON CONTROL BOARD
CONNECTION # WIRE COLOR NORMAL VALUE
WHAT ARE YOU CHECKING?
D
W6 - BL4 DC144 - 192 V Does the fan motor have the proper voltage?
Y1 - BL4
DC4 - 10 V
(Pulse)
Is the fan motor producing regular pulse?
R3 - BL4 DC12 - 18 V Does the fan motor have the proper voltage?
E R5 - BK4 DC11 - 17 V Does the user interface have voltage?
H GY1 - GND AC1 - 100 V Flame rod detecting flame?
I
W12 - W13 5KΩ - 500KΩ Is the Over Heat Limiter OK?
BR9 - BK8
DC 2 - 5V
(Pulse)
More than 1,310
pulses/minute
Does the water flow sensor send a pulse?
(Only when water is flowing thru the unit)
R10 - BK8 DC 11 - 17V
Does the water flow sensor have voltage?
(Power ON; no water flow)
W7 - BK5
68°F = 10.3 k Ω
104°F = 4.9 k Ω
Is the water inlet thermistor working?
W13 - BK5
68°F = 10.3 k Ω
104°F = 4.9 k Ω
Is the water outlet thermistor working?
Y11 - BK5
68°F= 10.3 k Ω
104°F= 4.9 k Ω
Is the heat exchanger thermistor working?
R4 - BK5
68°F = 10.3 k Ω
104°F = 4.9 k Ω
Is the exhaust thermistor working?