EasyManua.ls Logo

Rheem Iconic RTGH-SR11i - Diagnostic Points on Control Board

Rheem Iconic RTGH-SR11i
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
IKONIC Tankless Water Heater Service Manual
14
GENERAL INFORMATION
1.3 DIAGNOSTIC POINTS ON CONTROL BOARD
FAN MOTOR
VENTILATEUR DU MOTEUR
FM
DISPLAY
AFFICHAGE
COLOR CODE
CODE COULEUR
REMOTE RECIRC EXT1
CTRL RECIRC.1
R:
W:
BR:
BK:
BL:
GY:
G:
O:
Y:
G/Y:
P:
RED, ROUGE
WHITE, BLANC
BROWN, MARRON
BLACK, NOIR
BLUE, BLEU
GRAY, GRIS
GREEN, VERT
ORANGE, ORANGE
YELLOW, JAUNE
GREEN / YELLOW,
VERT / JAUNE
PINK, ROSE
GAS CONTROL MOTOR
MOTEUR COMMANDE
DU GAZ
HOT WATER OUTLET THERMISTOR
THERMISTANCE SORTIE D'EAU CHAUDE
EXHAUST THERMISTOR
THERMISTANCE ÉVACUATION
WATER INLET THERMISTOR
THERMISTANCE ENTRÉE D'EAU FROIDE
HEAT EXCHANGER THERMISTOR
THERMISTANCE ÉCHANGEUR DE CHALEUR
WATER FLOW SENSOR
CAPTEUR DE DÉBIT D'EAU
MOTEUR MÉLANGE D'EAU
WATER BY-PASS
CONTROL MOTOR
MOTEUR DÉBIT D'EAU
WATER VOLUME
CONTROL MOTOR
GAS TYPE CIRCUIT BOARD
CIRCUIT BOARD
CARTE ÉLECTRONIQUE
WIRING DIAGRAM
SCHÉMA DE CÂBLAGE
IGNITER
ALLUMEUR
IG
GAS-AIR-RATIO VALVE
VANNE RATIO GAZ-AIR
G.A.
R.V.
RESISTOR
RÉSISTANCE
AC
120V
SOLENOID VALVE 1
ÉLECTROVANNE 1
SV1
FOR PUMP BUILT-IN MODEL
MODÈLE AVEC POMPE
WHEN YOU CHANGE PCB,
PLEASE REMOVE THESE SCREWS
OVER HEAT LIMITER
LIMITEUR DE SURCHAUFFE
FLAMEROD
DÉTECTEUR DE
FLAMMES
GND
GND
GND
41-23050 4
PUMP
6 5 4 3 2 1
1
1
1
3
5
7
9
6
8
10
11 12
13
15
15
13
11
9
8
6
4
2 1
3
5
7
16
14
12
10
16
14
4
2
2
2
3
3
4
4
5
6
5 4 3 2 1
1
2
3
4
5
6
7
8
1
2
3
4
5
1
2
3
4
5
6
7
8
9
10
11
12
13
D
W
W
W
W
R
R
W
BK
5 6
BKBK
BK
BK
G/Y
or
G
G/Y
G/Y
W
W
W
H
BK
W
GY
W
Y
BK
BK BK
GY
GY
W
BK
BR
R
Y
W
W
BK
R
G
Y
BL
O
W
BR
BK
R
G
Y
BL
O
W
BR
BR
BK
BL
W
Y
G
R
O
W
BK
BL R O Y
R Y W G
BK BRBLW O Y
Y
W
G
BK
R
G R
BK or W
BK or W
BK or W
BK or W
W
W
BK G W O YR BRBL BK G WO YR BRBL
R
BK
BR
W
W
BK
J
C
I
A
G
B
E
F
LIMITER
LIMITEUR
MOTOR
MOTEUR
PLAQUE DE CIRCUIT
IMPRIM
É
TYPE GAZ
LIMITER
LIMITEUR
MOTOR
MOTEUR
LIMITER
LIMITEUR
MOTOR
MOTEUR
W BL
WATER LEVEL ELECTRODE
ÉLECTRODE DE NIVEAU D'EAU
BL
R
R
R
BK
R
R
CONNECTION # WIRE COLOR NORMAL VALUE
WHAT ARE YOU CHECKING?
A
W1-BK2 AC108 - 132 V
Do you have power to the control
board?
W3-BK4 AC108 - 132 V Do you have power to the pump?
C
GY1-GY4 AC108 - 132 V Is the igniter working properly?
Y3-BK5
DC90 - 120V
0.8kΩ - 2.4kΩ
Solenoid valve 1 OK?
W6-BK2 AC108 - 132 V Gas - Air - Ratio valve OK?

Table of Contents