EasyManua.ls Logo

Rheem Iconic RTGH-SR11i - Blower

Rheem Iconic RTGH-SR11i
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
IKONIC Tankless Water Heater Service Manual
73
HOW TO REMOVE COMPONENTS
3.12 BLOWER
1. Remove fan control wiring harness from control
board (Connector “D”) and wire holder from the
bracket.
2. Remove solenoid valve wiring connecting to gas
orifice block.
3. Remove heat exchanger bracket located top of
center on water heater.
4. Remove the gas orifice block by removing the sev-
en black screws holding it in place.
NOTE: After removing the gas orifice block,
secure four (4) gaskets in a safe location to
avoid loss.
5. Remove the two screws securing the fan assembly.
6. Remove fan assembly according to the following
graphic.

Table of Contents

Related product manuals