IKONIC Tankless Water Heater Service Manual
72
HOW TO REMOVE COMPONENTS
3.10 IGNITER COIL 3.11 IGNITER ROD
1. Remove the hook film part of the Over Heat Limiter
(OHL).
2. Remove Igniter rod cover.
3. Remove igniter coil wire from igniter rod (right side).
4. Remove white Molex connector from igniter coil.
5. Remove the screw (pictured below) from the igniter
bracket.
1. Remove the hook film part of the Over Heat Limiter
(OHL).
NOTE: DO NOT cut the film.
2. Remove igniter rod wire.
3. Remove 3 screws from rod bracket, and remove
the igniter rod.
NOTE: When reassemble igniter rod, please
use a spare gasket if the condition of the gas-
ket is not good.
The spare gasket is located at lower left in the unit
Flame Rod
White Molex Connector
Igniter Rod
Screw
Flame Rod
Igniter Rod

Table of Contents