ANTI-CONDENSATION HEATER 10 August, 2001
3-48
3.16 ANTI-CONDENSATION HEATER
!
CAUTION
Unplug the machine power cord before starting the following procedure.
1.  Remove the rear scale [A] (3 screws), left scale [B] (2 screws), and exposure
glass [C].
NOTE: When reinstalling the exposure glass, make sure that the mark [D] is
positioned at the rear left corner, as shown.
2.  Move the 1st and 2nd scanners to the right.
3.  Install the cable clamp [E].
4.  Install the anti-condensation heater [F] (2 screws).
5.  Join the connectors [G]
6.  Attach the cable cover [H], as shown.
B027I001.WMF
B027I304.WMF
[A]
[B]
[C]
[D]
[E]
[F]
[G]
[H]