EasyManua.ls Logo

Ricoh PRO C7210X - Page 116

Ricoh PRO C7210X
685 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1.SC Codes
112
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
Thermopile disconnected or defective
Thermistor disconnected or defective
Reconnect or replace the Fusing Thermistor (Roller Shaft)
Replace the fuser unit.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC579-
02
A
Sensor 8: Fusing Thermistor (Roller Shaft) disconnected 2
When temperatures lower than 50°C are detected continuously for 1055 seconds
or more, SC occurs. (Excluded time: 400 seconds are excluded.)
The monitoring cycle is 100 ms.
Thermopile disconnected or defective
Thermistor disconnected or defective
Reconnect or replace the Fusing Thermistor (Roller Shaft)
Replace the fuser unit.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC580-
01
D
Temperature Decrease Detection: Heating Roller Thermopile
Disconnection during paper feed
The thermopile detected -10 degrees less than target temperature after correction
continuously for 150 seconds or longer during or after paper feeding
Removal time: 50 seconds (excludes removal time)
Replace the fusing lamp.
Replace the Heating Roller Thermopile.
Replace the Fuser Unit.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC581-
01
D
Secondary Power Cord Not Connected
The main power cord is connected but the secondary power cord is not
connected.
The secondary power cord is not connected.
Circuit breaker is off.
Harness broken
AC drive/IOB defective.
Turn the machine off and plug in the secondary power cord again.
Check that the circuit breaker is on. If off, turn it on.
Replace the harness.
Replace the AC drive/IOB.