1.SC Codes 
130 
Error Name/Error Condition/Major Cause/Solution 
BCU_EEPROM Data read: Communication timeout error 
BCU_EEPROM Data read: Operation stopped error 
BCU_EEPROM Data read: Buffer full 
BCU_EEPROM Data read: No error code 
BCU_EEPROM Device detection: ID error 
BCU_EEPROM Device detection: Channel error 
BCU_EEPROM Device detection: Device error 
BCU_EEPROM Device detection: Communication abort error 
BCU_EEPROM Device detection: Communication timeout error 
BCU_EEPROM Device detection: Operation stopped error 
BCU_EEPROM Device detection: Buffer full 
BCU_EEPROM Device detection: No error code 
Verify error on SRAM expansion 
When the I2C communication is not established between BCU and EEPROM. 
  EEPROM not connected fully 
  EEPROM not installed 
  EEPROM damaged 
  BCU damaged 
Turn the power OFF then ON to check if the SC occurs. If the SC occurs again, do 
the following steps. After each step, turn the power OFF then ON to check if the 
SC occurs again.