1.SC Codes
145
SC NO.
Level
Error Name/Error Condition/Major Cause/Solution
07
When turning on the power, recovering from energy saving, and the door is
closed
SC690-04: Communication error between CRB-L (IPAC2) and IOB
SC690-06: PLL error for CRB-L (CANOPUS_LVDS)
SC690-07: PLL error for CRB-L (REGOR_LVDS)
Harness disconnected
Harness defective/shorted
CRB defective
IOB defective
1. Cycle the main power switch off/on.
2. Reconnect the harness between CRB-L and IOB.
3. Replace the harness between CRB-L and IOB.
4. Replace the CRB-L.
5. Replace the CIS.
6. Replace the IOB.
SC NO.
Level
Error Name/Error Condition/Major Cause/Solution
SC691-
03
B
TIM-Mag error 2: after fusing: serial communication error: front CIS
SC691-
06
B
TIM-Mag error 2: after fusing: serial communication error: rear CIS
SC691-
07
B
TIM-Mag error 2: after fusing: connection detection error: front CIS
SC691-
10
B
TIM-Mag error 2: after fusing: connection detection error: rear CIS
SC691-11
B
TIM-Mag error 2: after fusing: black level adjustment error: front CIS
SC691-
14
B
TIM-Mag error 2: after fusing: black level adjustment error: rear CIS
When turning on the power, recovering from energy saving, and the door is
closed
SC691-03: Communication error between CIS front and IOB
SC691-06: Communication error between CIS rear and IOB
SC691-07: Connection error between CIS front and CRB-L
SC691-10: Connection error between CIS rear and CRB-L
SC691-11: CIS front black level adjustment error
SC691-14: CIS rear black level adjustment error