1.SC Codes 
198 
Error Name/Error Condition/Major Cause/Solution 
  Replace the right power supply fan 
  Replace the slave board. 
  Replace the motor harness. 
 
Error Name/Error Condition/Major Cause/Solution 
Perfect Binder: Power supply fan (center) lock error 
  Center power supply fan overloaded, defective 
  Slave Control Board defective 
  Reconnect the connector. 
  Replace the center power supply fan 
  Replace the slave board. 
  Replace the motor harness. 
 
Error Name/Error Condition/Major Cause/Solution 
Perfect Binder: Left power supply fan lock error detected 
  Left power supply fan overloaded, defective 
  Master control board defective 
  Reconnect the connector. 
  Replace the left power supply fan 
  Replace the master control board. 
  Replace the motor harness. 
 
Error Name/Error Condition/Major Cause/Solution 
Perfect Binder: Spine plate fan (front) lock error 
Front spine plate fan failed to generate a lock signal within 12 sec., and signal 
could be detected even after a re-try. 
  Front spine plate fan overloaded, defective 
  Slave Control Board defective 
  Reconnect the connector. 
  Replace the front spine plate fan. 
  Replace the slave board. 
  Replace the motor harness. 
 
Error Name/Error Condition/Major Cause/Solution 
Perfect Binder: Spine plate lower fan (right) lock error