1.SC Codes
225
Error Name/Error Condition/Major Cause/Solution
Replace the slave control board.
Replace the sensor harness.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: LE detect sensor adjustment high value error
The leading edge detect sensor A/D input value was lower than 3.2 to 3.54V, and
the A/D input value did not go higher than 3.2 to 3.54V, even after cover
registration sensor A/D output value output was higher than 3.7V.
LE detect sensor connector loose, broken, defective
Sensor defective
Slave control board disconnected, defective
Reconnect the connector.
Replace the LE detect sensor.
Replace the slave control board.
Replace the sensor harness.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Entrance path sensor adjustment high value error
When the entrance path sensor was adjusted, the sensor A/D input was less than
2.58 V, even after the sensor D/A output was more than 3.3V.
Entrance path sensor connector loose, broken, defective
Sensor defective
Cutter control board disconnected, defective
Reconnect the connector.
Replace the entrance path sensor.
Replace the cutter control board.
Replace the sensor harness.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Book registration sensor adjustment high value error
When the book registration sensor was adjusted, the sensor A/D input was less
than 2.58 V, even after the sensor D/A output was more than 3.3V.
Book registration sensor connector loose, broken, defective
Cutter control board disconnected, defective
Reconnect the connector.
Replace the book registration sensor.
Replace the cutter control board.