1.SC Codes
347
Error Name/Error Condition/Major Cause/Solution
Replace the signature path exit HP sensor.
Replace the slave control board.
Replace the motor harness.
Replace the sensor harness.
After the repairs, cancel the low performance mode, and then turn the power
off/on.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Signature exit path HP sensor lag error
During signature exit roller nip operation, the signature exit path sensor did not go
OFF, even after the signature exit path motor was OFF for 300 ms.
Signature path exit motor defective
Signature path exit HP sensor defective
Connector loose, broken, defective
Slave control board defective
Reconnect the connector.
Replace the signature path exit motor.
Replace the signature path exit HP sensor.
Replace the slave control board.
Replace the motor harness.
Replace the sensor harness.
After the repairs, cancel the low performance mode, and then turn the power
off/on.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Signature path exit press sensor late error
During signature exit roller nip operation, the signature exit path exit press sensor
did not go ON, even after the signature exit path motor operated for 300 ms.
Signature path exit motor defective
Signature path exit press sensor defective
Connector loose, broken, defective
Slave control board defective
Reconnect the connector.
Replace the signature path exit motor.
Replace the signature path exit press sensor.
Replace the slave control board.
Replace the motor harness.